Area Calculation Clarification - The Building Code Forum
2011年10月14日 · Party walls are "fire walls" by IBC description (See Section 706.1.1, 2009 IBC). Therefore, buildings area is measured to the face of the wall on the side that is being measured; thus, the party/fire wall is not included in the building area (see the "building area" definition).
Occupancy Classification for Townhouse: R-2 or R-3?
2009年10月17日 · 2018 IBC 903.3.1.3 NFPA 13D Sprinkler Systems: "Automatic sprinkler systems installed in one- and two-family dwellings; Group R-3; Group R-4, Condition 1; and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D."
Minimum Exterior Lighting Requirements - The Building Code Forum
2009年10月16日 · 2018 IBC 1008.2.3 Exit discharge. Illumination shall be provided along the path of travel for the exit discharge from each exit to the public way. Exception: Illumination shall not be required where the path of the exit discharge meets both of the following requirements: 1.
Fire rating of electrical equipment rooms - The Building Code Forum
2010年12月17日 · For example access to the room may be from a corridor that requires a 1-hour partition in accordance with the IBC section for corridors; see 2012 Section 1018 or 2015 Section 1020 In shopping malls it is a 1-hour fire barrier in accordance to Section 402.8.7 Another condition is the exterior wall fire-separation may require minimum rating.
Occupancy for small conference/break rooms - The Building Code …
2013年3月12日 · Using 2009 IBC, I believe the correct loading would be to use an assembly loading from Table 1004.1.1 for a break room or conference room. In your scenario, what is 750 sq ft - the entire tenant space or the conference room alone? Assume this type of scenario: A conference room (for employees only) in a multi-floor office building.
Group E daycare - The Building Code Forum
2019年10月1日 · 2015 IBC Chp 308.6.1, “A child day are facility that provides care for more than five but not more than 100 children 2 ½ years or less of age, where rooms in which the children are cared for are located on a level of exit discharge serving such rooms and each of these child care rooms has an exit door directly to the exterior, shall be ...
Water storage ideas - IBC Totes? | Survivalist Forum
2011年7月2日 · I have seen people on SB mention the IBC water totes that hold 275 gallons. I don't know where to acquire and how to fill / retrieve the water out. We have both barrels stored in the basement on the slab cement floor with thick rubber pads …
Occupant Load Factors for a Restaurant - The Building Code Forum
2016年1月18日 · 2012 IBC I'm designing the renovation of an existing restaurant and need to determine the occupant load. Besides needing to know this for egress, the owners want to know how much seating they can put into the space. I know the kitchen qualifies as a commercial kitchen: 200 gross sf per...
IBC Tote Cover Ideas - Survivalist Forum
2016年6月27日 · It is a black & white poly film 5.5 mils thick. It's white on one side and black on the other. Wrap the IBC like a Christmas present with this film white side out. It is 80% reflective and 100% opaque. This will keep the contents of the IBC cool in direct sunlight whereas black plastic will turn your IBC into a water heater.
IBC Tote - Algae and Paint - Survivalist Forum
2014年10月15日 · Just joined you folks. Looking for what kind of paint to use on IBC Totes for algae. What a wakup call. I'm not taking any chances as to who or what is most accurate. So glad I didn't just go ahead and take the word of a used IBC Tote dealer in Austin,TX that appears to be just getting into the business by only being open 3 hours a day.