R22 vs R404 differences - HVAC-Talk
2012年5月8日 · R404 is a better A/C refrigerant because of the lower temps but works like R410 in heating. The discharge temps are lower than the normal for what an R22 system would see. The new dry R22 units have mineral oil in them so they are already compatable with R404. Many are starting to use that since the price of R22 is getting bad.
superheat on r-404a - HVAC-Talk
2014年6月6日 · yeah, That's why I'm throwing this out there. I was thinking maybe with the low temp. that a swing to the minimum 3 deg. S.H. might be o.k.
Walk in cooler, Replace equipment using R407C or R404A?
2015年1月25日 · Join Date Jul 2011 Location Lehigh Valley, PA Posts 510 Post Likes Likes (Given) 3 Likes (Received) 5 Dislikes (Given) 0 ...
R404 walk in - HVAC-Talk
2021年7月6日 · I’m n ac guy trying to help a buddy with walk in with r404. Can only get 20 degrees super heat liquid temp 112. 305 psi. Suc 50 psi. This is a new start up Txv is open all the way. Site glass is full amp 17 amp rated 22. Outdoor temp 82 box 45
r410a vs r404a - HVAC-Talk
Join Date Sep 2013 Posts 2 Post Likes Likes (Given) 0 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received) 0
Normal Freezer Pressures - HVAC-Talk
2012年7月9日 · Join Date Jan 2010 Posts 49,194 Post Likes Likes (Given) 15933 Likes (Received) 18436 Dislikes (Given) 94 Dislikes (Received)
R22 vs R404A - HVAC-Talk
2015年9月21日 · To get a good idea of what to expect in capacity difference when using different refrigerants in the specific condensing unit, I have copied a section of the condensed capacity ratings for the Copeland Model FFAP-015Z, which is a multi-Refrigerant unit designed for use with R404A, R134A, R407C and R22.
R404A Freezer - HVAC-Talk
2006年11月17日 · First time using and installing a freezer split system with 404A. Can some one tell me LP,HP settings. Box is using a LL Soleniod for pump down operation with stat.System is air cooled walk in box.
404a walkin freezer - HVAC-Talk
2011年6月24日 · i am dealing with a walk in freezer temp is 40 degree in box no lower sight glass is clear running 20psi on suction and 325psi on head pressure evap sh is 56 100 degree ambient temp my evap is obviously starved big time. expansion valve raised 6 psi when holding it in my hand everything is sized correctly with brandnew expansion valve (flare in) any feedback …
r22 convert to r404 for med temp - HVAC-Talk
2007年7月2日 · compressor is a 3RA1-0310-TAC AT 20/120 33300 BTU listed with r502, COMPARED TO 25800 BTU WITH R22. THE DELI CASES REQUIRE 26000 BTU.