Eaton’s Bussmann series range of 12 kV DIN Medium voltage fuse links are suitable for transformer protection. These fuse links can be used even where there is no secondary LV protection, provided they are used with fuse switches fitted with instantaneous striker tripping.
L078164 - 45ASB72V63P-2 Fuses | Mersen
High Voltage Back-up fuse for motor Limitor® 7.2kVAC IEC 63A Size d=50.8mm, L=292mm With Striker 20N Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades.
MEDIUM VOLTAGE DIN Fuse-Links MV DIN 12kV, Current Limiting Back-Up Fuse-Links, 6.3 to 200 Amps Form No. 12kV DIN Page 1 of 13 Data sheet 720104 Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Description: A range of medium voltage DIN Fuses, complete with sealed striker, suitable for transformer ...
12KV 160AMP 3" DIN FUSE 12TFMSJ160 EATON ELECTRIC Fuse-lin..
Buy 12KV 160AMP 3" DIN FUSE 12TFMSJ160 EATON ELECTRIC Fuse-link, medium voltage, 160 A, AC 12 kV, 3", 76 x 442 mm, back-up, DIN, with striker the best price,..
Eaton Bussmann series medium voltage DIN fuse - SFLDJ-12KV…
Eaton Bussmann series medium voltage DIN fuse, 12kV,63A,50kA breaking capacity,76mm diameter,292mm length,Spring striker,Transformer protection,Medium voltage DIN fuse. ... 720104 12kV DIN medium voltage fuses. Download all files Eaton is an intelligent power management company dedicated to improving the quality of life and protecting the ...
TDLEJ, THLEJ & TXLEJ Fuses (12kV, DIN 43625) - Advanced …
TDLEJ, THLEJ & TXLEJ Fuses (12kV, DIN 43625) Shipping calculated at checkout. Description: MV Fuse link complete with sealed striker. Suitable for transformer protection. Suitable for operation in AIR or TRANSFORMER. Voltage: 12kV. Amperages: 6.3A, 10A, 16A, 20A, 25A, 31.5A, 40A, 50A, 63A, 80A, 100A, 125A, 160A, 200A. Overall length: 292mm.
Limitor® - aSJB/D Back-up Fuses, 3,6kV to 12kV - with striker
Mersen HV fuse link for motor protection is specially designed to protect HV motors against the effect of short circuit current and support repeated peak currents due motor starting. Mersen uses the best materials : fuse elements are in pure silver, caps are in silver-plated brass and body is in melamine fiber glass.
12KV HRC Medium Voltage Fuses - Aidun Electric
China Fuse Manufacturer Aidun Electric produce "Solarson" brand A range of 12KV HRC Medium Voltage Fuses for Transformer Protection with striker, suitable for transformer protection.The fuses can be used even when there is no secondary low voltage protection, provided they are used with fuse switches fitted with instantaneous striker tripping.
High-voltage high breaking capacity fuses type SSK for the protection of high power transformers with a special alignment to the rated transient current of switch-fuse combinations according to EN 62271-105 H.v.h.b.c. fuses with striker type SSK and thermal protection up to 125 A
In order to be current limiting, the fuse link must generate an arc-voltage exceeding the instantaneous value of the operating voltage. The switching voltage generated by the CEF fuse link is below the maximum permissible value acc. to IEC 282-1. The CEF fuse link can safely be usedifthesystemlinevoltageis50-100%oftheratedfuselinkvoltage.