
ACSR Beaver Conductor 70mm2 Application: - Hongda Cable
ACSR Beaver Conductor 70mm2 Features: With simple structure, the aluminum conductor steel reinforced is easy to set up and maintain, with low cost and high transmission capacity. It is advantageous for this ACSR to be put up across a valley or river or under other various special geographic conditions.
ACSR – Aluminum Conductor Steel Reinforced is used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding for desired strength to be achieved without sacrificing ampacity. CONDUCTORS: • Aluminum alloy 1350-H119 wires, concentrically ...
ACSR - Southwire
Southwire's ACSR bare conductor meets or exceeds the following ASTM specifications: B230 Aluminum 1350-H19 Wire for Electrical Purposes; B232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR). B498 Zinc-Coated (Galvanized) Steel Core Wire for Use in Overhead Electrical Conductors.
(ACSR) SPLN 41-7:1981 DIMENSIONAL & MECHANICAL DATA ELECTRICAL DATA Cross No. of Wire/ / Diameter Approx. Cross Max. DC Sectional Area Approx. Net Weight Sectional Area Conductor Calculated Current Standard Nominal Actual Al Steel Overall of Nominal Actual Resistance Breaking Carrying Quantity
Aluminum Conductor Steel Reinforced (ACSR) #Martin - OmniCable
ACSR, a non-homogenous conductor, is a concentric-lay-stranded conductor made from round aluminum 1350-H19 (extra hard) wires and round, coated steel core wire(s)
ACSR Beaver Conductor 70 (BS) - GE Cable
ACSR (aluminum conductor steel reinforced) has a long service record because of its economy, dependability, and strength to weight ratio. The combined light weight and high conductivity of aluminum with strength of the steel core enables higher tensions, less …
70 ACSR Beaver Conductor - LZ Cable
ACSR Beaver Conductor is suitable for use in all practical spans on wood poles, transmission towers, and other structures. Applications range from long, extra high voltage (EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises.
ALUMINUM CONDUCTORS STEEL REINFORCED ( ACSR ) Approx. Maximum dc Code overall Rated resistance Name Steel Total Aluminium Steel diameter Aluminium Steel Total Strength at 20 oC AWG or AWG or MCM MCM TURKEY 6 13.30 2.22 15.52 8 8.39 6/1.68 1/1.68 5.04 36.5 17 54 5.28 2.1499 THRUSH 5 16.83 2.81 19.64 7 10.58 6/1.89 1/1.89 5.67 46.0 22 …
Bare Aluminum Conductor Steel Reinforced (ACSR) - Philflex
PHILFLEX Type Bare ACSR conductors are primary used in overhead transmission lines, distribution lines requiring heavy tensile load. Specifications: PHILFLEX Type Bare ACSR meets and exceeds applicable ASTM B 232 specifications.
ACSR - CADIVI
Dây nhôm lõi thép – ACSR (As, AC) sử dụng cho đường dây tải điện trên không. Tại các vùng biển hay các miền không khí có tính ăn mòn kim loại cao, dây nhôm lõi thép trần được tra mỡ trung tính chịu nhiệt có nhiệt độ chảy nhỏ giọt không thấp hơn 120 0 C.
- 某些结果已被删除