Replacing a Capillary Array on your Parallel Capillary …
2022年11月10日 · Learn how to effectively maintain and operate your Agilent parallel capillary electrophoresis system: 5200, 5300, and 5400 Fragment Analyzer System Manual on Agilent.com Femto Pulse User Manual on Agilent.com Oligo Pro II User Manual on Agilent.com ZAG DNA Analyzer System Manual on Agilent.com ProteoAnalyzer System Manual on Agilent.com
How to Use the Browser Interface for 8890 and 8860 GC Systems
2022年11月10日 · This Information Applies To: Agilent 8890/8860/Intuvo 9000 GC Systems Issue When you are working on troubleshooting an Agilent GC system with an Agilent support representative, you may need to provide the GC diagnostics logs. This article shows how to get the files from the browser interface of the 8890, 8860 and Intuvo 9000 GC Systems.
How to Check, Configure and Use the IP Address of an Agilent …
2022年11月10日 · Agilent HPLC modules can be configured to use either a default IP address (192.168.254.11) that cannot be changed (static), or a stored IP address that can be defined by the user. The position of the configuration switches that are on the back of an LC module determines which IP address the module uses.
How to Configure an HPLC Instrument in the Agilent OpenLab …
2022年11月10日 · If you have not yet created your HPLC instrument, under OpenLab Control Panel > Instruments, select Instruments to highlight it. Then, on the top left, click Create > Create Instrument. Give the instrument a name and select the Instrument type Agilent LC System or Agilent LC & LC/MS (for OpenLab CDS 2.X). Optionally, you can put a description ...
Run 2 or more instruments with one PC running OpenLab CDS
2024年12月2日 · Unfortunately both these instruments have SQMS:s, so it seems it won't work anyway. I asked because my employer is hesitant to upgrade the license for the instrument running the old Chemstation. I highly prefer the modern CDS, everything is better and faster. It is mostly a cost issue, as it always is. But thanks anyway.
ICP-OES Detector and Instrument Calibration - Agilent Technologies
2022年11月10日 · This Information Applies To: Agilent 700 Series ICP-OES instruments Issue: It is important that a torch alignment is performed to ensure that the optics are optimized and are focused on the analytical zone of the plasma. This alignment procedure will ensure maximum sensitivity and signal-to-noise.
Helpful Resources for Maintaining Laboratory ... - Agilent …
Here are links to helpful webinars and documents, with respect to shutting down instrumentation for a significant period of time in your laboratory, as well as bringing the equipment back on-line, and cleaning and disinfecting your Agilent instruments during Covid-19. Webinar Series: Preparing your laboratory - Best Practices for Temporary Closures
How to Reset the AVS 6/7 on Agilent ICP-OES Instruments
2022年11月10日 · This Information Applies To: Agilent 5000 Series ICP-OES Systems, AVS 6/7 Issue Over time the AVS 6/7 rotor can become worn or damaged by chemicals. Agilent recommends inspecting and/or replacing the rotor every 5000 AVS switches or when analytical results or precision fall outside expected limits.
Step 13. Configure GC/MS Instruments 11 In the Agilent GC/MS Instrument Configuration window, select the Gas Chromatograph Model of your instrument from the drop down menu: • None • Other • 7890 GC • 7820 GC • 7810 GC (5975T) • 6890N GC • 6850 GC 12 Enter the IP Address of your gas chromatograph.
Are the Parallel Capillary Electrophoresis Assays Denaturing?
2024年10月10日 · In contrast to the other Agilent parallel capillary electrophoresis instruments, the ProteoAnalyzer is used for protein analysis. The 10x Labeling Buffer in the Protein Broad Range P240 kit (p/n 5191-6640) contains denaturing reagents and the protocol contains a heat denaturing step.