Mitsubishi branch box vs. port-type service: Do the indoor units …
2019年4月3日 · I have a MXZ-8C48NAHZ with a 5 port branch box in the basement (see picture). MLZ Positives: To me the MLZ looks better than wall units but probably the biggest positive of the MLZ’s to me is the built in condensate pump which, combined with running the refrigerate lines above the unit, makes it easier to install away from exterior walls and minimize outdoor …
Mitsubishi Mini Split Branch Box Location - Heating Help
I have a 5 zone mini split being installed in my house. The branch box is to be located in the attic. However I noticed this verbage in the installation manual “ Do not install the branch box in location that is hot and humid for long periods of time “. I live in Missouri so it gets really hot in the attic even on 75 degree days.
branch boxes for multizone ductless heat pump
2025年2月13日 · The smaller multi splits with many ports essentially have the branch box built in. Where it gest confusing is the newer Mitsubishi SM units. The SM series have SM specific indoor units which have all the branch box smarts built in so you can hook it up to an SM outdoor unit simply with a bunch of refrigerant splitters.
Mitsubishi 3 Zone 36K Ductless Question (Branch Box Needed Or …
Now -- using a branch box changes everything. There is a whole other table for that and I could have made a 3 head work in my new build if I had used the Branch box -- there you get more capacity. I ended up using 3 singles. It was a cleaner install and I had no way of hiding the two fan unit that was going to be required.
Minimum Line Length Between Branch Distributor Box and …
My line length from the condenser to the Branch Box is ~10m and the line sets from the branch box to 2 of the evaporators is is about 15m each. The 3rd evaporator sits right next to the branch box, so in a perfect world my line length would only be ~2m to that unit. But LG says that no individual line set should be less than 5m.
Hate to ask again about Mitsubishi mini-split and when a branch …
2022年10月14日 · The question is whether we need a branch-box or not? If we go to 3 KP12NA heads does that increase in capacity on the system then require a branch-box? Last question - any issue with a lineset run on one of the heads at about 72 feet? Really appreciate any info as there's just not an easy way to find this info elsewhere. Thanks very much.
Mitsubishi mini split branch box efficiency - GreenBuildingAdvisor
2020年9月22日 · Which are the 3 zone non-branch box and 4 zone branch box, the 4 zone at cold temperature has higher COP. At least for Mitsu, the branch box doesn't effect efficiency. In your case, I would leave the existing no-hyper heat units, but get a …
Branch box location question - GreenBuildingAdvisor
2017年10月27日 · I have a similar question about branch box location. My installer who worked with Mitsubishi to get the details fine tuned says that a branch box can be installed outdoors as long as its protected from the elements. The manual itself says that its possible as long as you use an accessory box, which is essentially a sheet metal box.
Mitsubishi line-set minimum length FH06na? - GreenBuildingAdvisor
2019年12月9日 · I know there is a 10ft minimum length between an outdoor unit and a branch box, but I'm not sure what it is for a 1:1 system. willymo | Dec 09, 2019 11:58am | #3 Mitsubishi tech support says no minimum; other forums suggest that noise (vibration through the lineset) can be a problem with short linesets.
Smaller multi head mini split system using branch box
Trying to find out if there is a lower Btu (1.5-2 ton) mini split system that uses a branch box. I have a new addition highly insulated that could use a 3 head system. But since the walls are reinforced concrete (ICF) it will be difficult to run 3 refrigerant lines to the exterior.