Flexible Gas Line Underground - InterNACHI®️ Forum
2010年11月23日 · CSST mechanical fittings are not allowed or permitted inside the conduit. sfogarty (Sean Fogarty) November 23, 2010, 7:21pm 5
Ontario Gas Piping Question - InterNACHI®️ Forum
2013年6月4日 · Type of CSST gas line? Plumbing Inspections. 4: 6765: February 2, 2008 ...
Flexible gas piping OK for exterior? - InterNACHI®️ Forum
2007年8月1日 · CSST as a final connection of movable gas appliances, such as ranges and clothes dryers, is not allowed. CSST shall not be installed outdoors and shall not be run underground unless installed in a sleeve or conduit. A Corrugated Stainless Steel Tubing system utilizing a 2-psig or This is off the Peoples Gas Energy Guide. Chicago’s Gas Company
Gas flex line in crawl space - InterNACHI®️ Forum
2006年2月16日 · CSST is allowed in any location that other gas piping is allowed. If the flex gas line you were referring to was in fact, CSST, there may be no problem with that application. Also, CSST can pass through walls floors etc. If the flex gas line was actually an …
Bonding of csst gas line - InterNACHI®️ Forum
2020年6月18日 · Would appreciate some clarity on CSST bonding- a number of the posts I have read are confusing to me anyway. Is the clamp that is secured to the first csst fitting coming from the gas meter( or propane regulator) to then have the #6 copper wire run to the main service panel and attached to grounding bar in panel, or is it to go directly to agrounding rod.
Does CSST need the plastic coating around it?
2020年1月15日 · CSST isn’t rated for exterior use and the deterioration in your picture is exactly what happens. 2 Likes tewald (Terrill Ewald, CPI, MD# 31310) January 15, 2020, 7:23pm
CSST through solid wall - Plumbing Inspections - InterNACHI®️ …
2014年4月15日 · The thread title says “CSST through solid wall.” If this is the question, the answer is “yes,” CSST can pass through a solid wall. CSST can also be directly connected to fixed appliances. For the most part, it can be run in the same manner as black-iron pipe, with some exceptions for sleeves and protection from physical damage.
CSST gas lines - Inspecting HVAC Systems - InterNACHI®️ Forum
2009年3月28日 · The black “counterstrike csst” piping sold by Omegaflex and TracPipe does not need the additional bonding in my area but I expect this to eventually change. The additional bonding (equipotential bonding) typically requires a #6 or larger copper conductor between the main black iron gas pipe (with proper type clamp) at the meter and ...
Crawlspace gas line - InterNACHI®️ Forum
2020年8月20日 · 1/4" Gas Line that runs +40' to a grill. General Inspection Topics. 13: 575: July 2, 2023 Home ;
Bonding of csst gas line - Page 2 - InterNACHI®️ Forum
2020年6月18日 · That is what I thought so ur previous comment does not apply to csst bonding- just rigid pipe Thx. My comment about the CounterStrike is that it says to bonding according to NEC 250.104(B), that does not require a separated bonding conductor to the CSST.