Collar Tie Design - Structural engineering general discussion
2006年12月4日 · Can anyone provide a design resource for collar tie design for rafters. I have a contractor that has deviated from the requirements of the building code. Thanks
Collar tie - Structural Inspections - InterNACHI®️ Forum
2009年2月8日 · Collar ties go in the upper third of the roof and prevent uplift. Rafter ties go low in the roof and tie the bottoms of opposing rafters together to keep the tops of the walls from spreading and the ridge from sagging.
2x8 roof rafters, adding collar ties - Eng-Tips
2007年4月19日 · Any tips on strengthening 2x8 roof rafters? Collar ties currently exist on every 4th rafter. I'm thinking that adding collar ties at every rafter could easily increase capacity. Any tips? Suggestions? Warnings? Cautions? Thanks in advance.
Collar tie vs Ridge beam theoretical question - Eng-Tips
2022年7月6日 · Let's say you have a gable roof with collar tie & ceiling joists. If you install a new ridge beam just below the ridge board and you also keep the existing collar ties, am I right to assume you can remove the ceiling joists and use the existing rafters?
Collar Ties vs. Rafter Ties article upgrade. - InterNACHI®️ Forum
2014年1月23日 · Collar Ties vs. Rafter Ties - InterNACHI Learn about roof collar ties, rafter ties, ridge beams, bending moments, tension and compression.
How high do collar ties need to be? - InterNACHI®️ Forum
2008年1月7日 · Collar ties have to be in the upper third to be effective, but is there any limit on high they can be? For example, if the ceiling is 12’ high, the collar tie shouldn’t be *lower *than 8 feet.
Collar Tie Alternative Idea - Structural engineering general ... - Eng …
2024年6月27日 · I've been asked by one of my contractor clients about alternatives to collar ties for rafters in a space with a desired vaulted ceiling (residential construction). The contractor doesn't want to use the prescriptive minimum 1x4 wood framing due to loosing some ceiling height. The rafters are...
Collar Tie Design Residential Wood Framing - Eng-Tips
2019年3月25日 · While many of us engineers call Rafter Ties, Collar Ties, in some building codes, they are 2 totally different components that serve totally different purposes.
Cathedral Ceiling Rafter Thrust Load - Eng-Tips
2005年11月16日 · The collar ties are redundant because equilibrium is acheived by the vertical reactions at the ridge and the wall. If you do add collar ties to a system that has a structural ridge beam, I do agree that the collars will be loaded by the deflection of the rafter.
Roof Truss vs. Braced Ridge Beam vs. Bolted Collar Ties - Eng-Tips
2021年10月20日 · A collar tie and a rafter tie are two very different things and are very plainly defined in the code. Collar tie goes in the upper 1/3 and locks in the rafters at the ridge for unbalanced loading, rafter tie goes in the bottom 1/3 and resists spread. I do agree that the most effective place for a rafter tie is at rafter bearing.