
Garage overhang - GreenBuildingAdvisor
2020年6月16日 · I am building a 30 ft overhang with a metal roof over garage door and side door. I am using a 2x6s to secure bottom ledger into the header of the garage door, but there are only 2×4 s for the top ledger. I plan to run some 2×6 inside the garage vertically so the top ledger can sink into more than 2x4s.
Ideal roof overhang length? - GreenBuildingAdvisor
2012年11月30日 · First of all, I recommend this free online calculator for determining the size of a roof overhang for a passive solar design: Overhang Design. Second, a wide overhang is always better than a stingy overhang, as long as (1) the overhang isn't so wide that it interferes with solar gain in winter, and (2) the overhang doesn't make the house more ...
Cutting Off Portion of Existing Roof Overhang
2021年5月30日 · As Kyle said, there is no structural reason stopping you cutting them back flush with the exterior wall. However that overhang may well be what keeps the existing wood siding dry and in fair shape, as well as stopping water from penetrating the wall. Think through carefully where you cut the overhang back to.
Do generous overhangs need venting or insulation?
2018年5月26日 · I plan to have a contractor take the soffit down this summer and take a look behind it. I think the most likely answer is to spray foam under the overhang, just like the heated portion of the house. This should bring the sheathing above dewpoint and hopefully stop condensation. Lukas - please make sure you don't run into the same issue.
Overhang Length - GreenBuildingAdvisor
2023年6月16日 · Garage overhang. Venting Soffit / Overhang. Replies. Expert Member Michael Maines | Jun 16, 2023 08:53am ...
Garage door flashing / sealing - GreenBuildingAdvisor
2018年9月18日 · If the door is close to an overhang above, the flashing could probably be omitted. I'm still not understanding where you are seeing daylight at the door track. They typically are mounted to brackets fastened through the drywall, and the door overlaps the 2"x trim.
House overhang insulation - GreenBuildingAdvisor
2024年2月19日 · - Block off the overhang over the foundation wall with pieces of foam board sealed with canned foam between the floor joists. This will stop air moving into the basement. - Put a layer of foam board under the overhang and cover with plywood (or other protective cladding) to reduce thermal bridging.
Air sealing and insulating detached garage with flat/low-sloping roof
2019年7月18日 · Happily the nearly flat, low-sloping roof was recently redone and the garage does not leak. The building has 2×4 walls, 2×6 rafters, plank sheathing on the walls and roof, painted cedar shingle siding with 11” reveals, and three tab roofing on the little decorative roof peak in front and some kind of continuous asphalt(?) sheeting on the ...
Designing a detached garage – concept review and general advice?
2024年1月9日 · Secondly, all the buildings should relate to each other. Your garage roof should reference your house roof (it can be a little different with an overhang) but by choosing a gable design the height of the eave over the garage doors will better protect them from rain (rather than the two story height of the shed roof).
Max overhang of a 2×4 rafter tail - Green Building Advisor
2019年7月27日 · If not, a 3 ft overhang as the eaves and a 2ft one on the gables would be easier and sturdier. You can use a beefier finished fascia to contribute to the rigidity of the gable ends. A 2"x8" attached to the rough fascia will help a lot. If they fit with the rest of the architecture, Craftsman style brackets would allow any depth overhang you wanted.