
CHAPTER 4 FOUNDATIONS - 2018 INTERNATIONAL RESIDENTIAL CODE (IRC)
The minimum width, W, and thickness, T, for concrete footings shall be in accordance with Tables R403.1(1) through R403.1(3) and Figure R403.1(1) or R403.1.3, as applicable. The footing width shall be based on the load-bearing value of the soil in accordance with Table R401.4.1 .
- [PDF]
CHAPTER 4
R403.1.4 Minimum depth. All exterior footings shall be placed at least 12 inches (305 mm) below the undisturbed ground. Where applicable, the depth of footings shall also conform to Sections R403.1.4.1 through R403.1.4.2. R403.1.4.1 Frost protection. Except where otherwise protected from frost, foundation walls, piers and other
2015 IRC foundations R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings, crushed stone footings, wood foundations, or other approved structural systems which shall be of sufficient design to accommodate all loads according to Section R301and to transmit
CHAPTER 4 FOUNDATIONS - 2021 INTERNATIONAL RESIDENTIAL CODE (IRC)
Foundations protected from frost in accordance with Figure R403.3(1) and Table R403.3(1) shall not be used for unheated spaces such as porches, utility rooms, garages and carports, and shall not be attached to basements or crawl spaces that are not maintained at a minimum monthly mean temperature of 64°F (18°C).
R403.1 - Digital Codes
R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings, crushed stone footings, wood foundations, or other approved structural systems which shall be of sufficient design to accommodate all loads according to Section R301 and to transmit the resulting loads to the soil within the ...
SECTION R403 FOOTINGS R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete foot¬ ings, crushed stone footings, wood foundations, or other approved structural systems which shall be of sufficient design to accommodate all loads according to Section R301 and to transmit the resulting ...
Chapter 4 Foundations
Foundations protected from frost in accordance with Figure R403.3(1) and Table R403.3(1) shall not be used for unheated spaces such as porches, utility rooms, garages and carports, and shall not be attached to basements or crawl spaces that are not maintained at a minimum monthly mean temperature of 64°F (18°C).
Chapter 4 Foundations: Foundations, California Residential
For buildings where the monthly mean temperature of the building is maintained at not less than 64°F (18°C), footings are not required to extend below the frost line where protected from frost by insulation in accordance with Figure R403.3(1) and Table R403.3(1).
Section R403.1.3.1 describes the existing requirements for the horizontal reinforcement at the top of the stem wall and the bottom of the footing. This proposal deletes that section and incorporates the language into the two sections describing the requirements for the stem wall, R403.1.3.1 and R403.1.3.2 respectively.
CHAPTER 4 FOUNDATIONS - 2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
The minimum width, W, and thickness, T, for concrete footings shall be in accordance with Tables R403.1(1) through R403.1(3) and Figure R403.1(1) or R403.1.3, as applicable. The footing width shall be based on the load-bearing value of the soil in accordance with Table R401.4.1 .