
Defining Adequate Lightning Protection Systems (LPS) for U.S. Army Ammunition and Explosives (AE) Facilities (Munitions Operating Facilities) This memorandum provides Army guidance for determining the adequacy of LPS for existing Army AE facilities and compliance with the above references. https://www.milsuite.mil/book/docs/DOC-370836
A properly maintained lightning protection system (LPS) is mandatory for ammunition and explosives (AE) facilities within the Department of Defense (DOD).
DOD CRITERIA FOR LPS ON AE FACILITIES DA PAM 385-64, Ammunition and Explosives Safety Standards o Applicable to Army Components o Section IV of Chapter 17 has LPS requirements o Implements safety requirements of DOD 6055.09-M AFM 91-201, Explosives Safety Standards o Applicable to Air Force Components o Implements in full DOD 6055.09-M
Lightning Protection | www.dau.edu
2015年2月28日 · 20 Jul 17 Lightning Protection Systems (LPS) for Contingency Locations within US Army Central's (ARCENT) Area of Responsibility (AOR) – Army Acceptance of Risk. Defining Adequate Lightning Protection Systems (LPS) for U.S.Army Ammunition and Explosives (AE) Facilities (Munitions Operating Facilities)
C7.2. LPS Design 73 C7.3. Inspection, Testing, and Training 74 C7.4. Lightning Protection Exceptions 75 CHAPTER 8 – HAZARD IDENTIFICATION FOR FIREFIGHTING 76 AND EMERGENCY PLANNING C8.1. Scope and Applicability 76 C8.2. Fire Divisions 76 C8.3. Fire Division Symbols 77 C8.4. Chemical Agent and Chemical Munition Hazard Symbols 77 C8.5.
LPS Army Abbreviation Meaning - All Acronyms
Army LPS abbreviation meaning defined here. What does LPS stand for in Army? Get the most popular LPS abbreviation related to Army.
Army TM 5-811-3 and Air Force AFM 88-9 Chapter 3, Electrical Design, Lightning and Static Electricity Protection. Description: UFC 3-575-01 provides policy and guidance for design criteria and standards regarding static electricity protection, lightning protection systems and related grounding for facilities and other structures.
Army Electrical Explosives Safety Course (Ammo 28)
Put the LPS components in the order in which the current flows after a lightening strike. 1. Strike determination device. 2. Down conductor. 3. Grounding system. Which image shows an example of an integral LPS? Which image shows an example of a mast LPS? Which image shows an example of a catenary LPS?
Local procurement of nonstandard ammunition and explosives (A&E) circumvents control, potentially exposing United States (U.S.) military and civilian personnel, to injury or death.
Army Electrical Explosives Safety (Ammo-28) Flashcards
Lightning can detonate munitions and explosives. Lightning seeks the path of least resistance to ground. Lightning cannot be stopped or prevented. Which statement is true about a mast LPS? Each mast must have two paths to ground. A 30-foot tall building is protected by a catenary system. How far from the building should the masts be placed?
- 某些结果已被删除