AP50 LN2 Ultrapure Fogger - Applied Metrology USA
AP50 LN2 Ultrapure Fogger with rolling, stainless steel enclosure, ≈ 8 M³ / Min. pure fog, ≈ 18 ft. visual distance, ≈ 480 M³ fog during 60 minute operation to visualize airflow turbulence in Clean Rooms, ISO Suites and Barrier Isolators. One 80mm fog outlet with velocity control, volume control & wireless control.
AP200 Ultrapure Cleanroom Fogger – Maximum Fog Volume for …
The AP200 Ultrapure Cleanroom Fogger is the most powerful liquid nitrogen (LN₂) fogging system in its class, designed for large-scale cleanroom validation, airflow visualization, and contamination control. Engineered for high-volume fog generation, the AP200 delivers industry-leading fog output, extended runtime, and u
Smoke Studies in clean rooms, iso suites, barrier isolators, glove ...
Ultrapure LN2 Fogger: This type of smoke generator or cleanroom fogger provides the highest fog volumes, best fog density and highest purity of fog. Purity is created by bringing the water to a high temperature, creating a vapor, while simultaneously using gravity to remove the residual mass from the vapor.
Smoke study and stage fog, Clean room Foggers from Applied …
Smoke Studies and smoke tests use an LN2 ultrapure fogger to visualize airflow patterns and turbulence! Fog Density is the controlling factor that enables a highly visual airflow for long distances. Fog density is a measure of how well you can track air movement; or how many fog vapor droplets are in a cubic centimeter of air.
AP100 LN2 Ultrapure Fogger - Applied Metrology USA
AP100 LN2 Ultrapure Fogger with rolling, stainless steel enclosure, ≈ 16 M³ / Min. ultrapure fog, ≈ 21 ft. visual distance, ≈ 1280 M³ fog during typical 80 minute operation cycle to visualize airflow turbulence in large Clean Rooms, ISO Suites and Barrier Isolators.
The Fog CapsuleTM consists of a cryogenic solenoid enclosed in protective foam insulation for easy and safe installation of LN2 Burst effects. The inner foam jacket is wrapped in a PVC insulating shell and all seams are sealed to provide a suitable vapor barrier. The Fog CapsuleTM is mounted in a Solenoid Mounting Bracket
AP35 Ultrapure Clean room Foggers from Applied Physics Inc.
LN2 fogger technology was developed in 2001 for smoke studies and air flow characterization in clean rooms. The fog output is adjustable from 2-5 cubic meters per minute. The AP35 complies with Semiconductor clean room guidelines, USP 797 Insitu Airflow Analysis and ISO 14644-3 visual airflow requirements to provide 3D airflow modeling in clean ...
Portable Cleanroom Fogger, CRF4 – Applied Physics Corporation
LN2 foggers use liquid nitrogen and DI Water or WFI water, providing the highest fog volume, highest fog density and best level of fog purity fog. Fog purity is allowing the LN2 to boil, while heating the water. nitrogen and water molecules form and combine at high rates to create a …
What are the fumes that form above liquid nitrogen?
2017年1月9日 · The visible fog that forms when liquid nitrogen is poured into an open container is almost entirely water fog: the boiling nitrogen chills the air above it, causing the humidity in the air to condense into fog.
AP35 LN2 Ultrapure Fogger - Applied Metrology USA
AP35 LN2 Ultrapure Fogger with rolling, stainless steel enclosure, ≈ 5 M³ / Min. ultrapure fog, ≈ 15 ft. visual distance, ≈ 225 M³ fog during typical 45 minute operation to visualize airflow turbulence in small Clean Rooms, ISO Suites and Barrier Isolators. One 80mm fog outlet with velocity control and volume control.