Residual Current Devices (RCD's)- NHP Australia
NHP’s DIN-T range of residual current devices (RCDs) are a high-performance electrical safety solution designed for commercial, industrial and mining applications. These RCDs offer a high level of selectivity, with sensitives including 10mA, 30mA, 100mA and 300mA, and types starting at Type A for general purpose applications through to Type F ...
NHP DIN-T Residual Current Devices - NHP Australia
NHP’s DIN-T Residual Current Devices (RCD) is a high-performance electrical safety solution offering a range of features. The RCD is designed to detect and trip on residual currents caused by earth leakage, improving the safety of personnel and equipment.
The trip sensitivity (Rated Residual Operating Current) of the RCD is the minimum level of earth leakage current required to operate the device. The selection of the trip sensitivity needs to take into account the purpose of the RCD. 10mA RCDs may be used in areas of increased risk such as circuits supplying outdoor equipment,
NHP 10A MOD6 RCBO 1P+ N 6Ka 30ma C-Curve
NHP MOD6 Residual Current Devices (RCD) offer peace of mind protection with a genuine 6kA rating and a proven history in domestic and commercial applications. The MOD6 RCD monitors the current flowing through the live and neutral wires of an electrical circuit, and if it detects an imbalance, it will quickly disconnect the power to prevent ...
Q: What RCD type? Type Description Use B Type B RCDs ensure tripping as described for Type F RCDs as well as: i) residual sinusoidal alternating currents up to 1000Hz. ii) residual alternating currents or pulsating direct currents superimposed on a smooth direct current current of 0.4 times the rated residual current.
NHP RCD Cover 2 Gang 198x101x45mm Gray ISORCDNPG
The NHP RCD Cover, identified by the product code ISORCDNPG, is designed to fit 2 gangs. With dimensions of 198x101x45mm and a gray color, this cover is intended to provide protection for Residual Current Devices (RCDs) in electrical installations.
- 评论数: 1
RCD testing What is Rapid Test: The Rapid Test System “RTS” is a Wi-Fi based RCD testing system which allows testing of RCD’s to be performed quickly and safely. Typically, RCD’s are tested either directly at the RCD expo-sing the electrician to the risks of live work, or at socket outlets located throughout the building which is more time
NHP 20 Amp MOD6+ MCB/RCD RCBO C Curve 1 Pole + Neutral …
The NHP 20 Amp MOD6+ MCB/RCD RCBO (Residual Current Breaker with Overcurrent Protection) is a reliable and efficient solution for protecting electrical circuits from both overcurrent and leakage faults. Designed with a 1 Pole + Neutral configuration, this RCBO features 30mA Type A sensitivity, providing effective protection against leakage ...
Residual Current Devices - NHP New Zealand
NHP’s DIN-T range of residual current devices (RCDs) are a high-performance electrical safety solution designed for commercial, industrial and mining applications. These RCDs offer a high level of selectivity, with sensitives including 10mA, 30mA, 100mA and 300mA, and types starting at Type A for general purpose applications through to Type F ...
NHP 10 Amp Miniature Circuit Breaker & Residual Current Device MCB/RCD ...
Various RCD types including AC, A, S, F and type B are available ensuring whatever the load(s) connected, you and/or the installation is protected from earth leakage currents; Wide range of trip sensitivity options to choose from with 10mA up to 500mA RCDs covering any application requirement; 6 or 10kA short circuit capacity available for RCBOs