PUG-7N – Technical Associates
The PUG-7N is a complete fast-slow Neutron monitor system. It includes the PUG-7, four-range survey meter with attached detection system: the MO-1 Moderator, and the PNS-20 Probe. The PUG-7N System, or Neutron PUG'' detects fast or slow neutrons by means of a thermal Neutron scintillation detector and a moderator.
Pug-7 Analog Radiation Detector - drct.com
The PUG-7 utilizes continuously adjustable regulated high voltage supply 1500V (2,500 volts on PUG-7A) to operate GM, scintillation gas proportional, BF 3, or He 3 detector delivering a one millivolt + pulse. An adjustable discriminator allows full control over system sensitivity.
PUG-7 – Technical Associates
The PUG-7 utilizes continuously adjustable regulated high voltage supply 1500V (2,500 volts on PUG-7A) to operate GM, scintillation gas proportional, BF3, or He3 detector delivering a one millivolt or above pulse. An adjustable discriminator allows full control over system sensitivity.
PUG Series | Technical Associates | Universal Survey Meter.
Description: The PUG-7-D electronics utilizes a continuously adjustable regulated high voltage supply of 1500V (Optional: 2,500 volts) to operate GM or scintillation detectors delivering one millivolt or above pulse. An adjustable discriminator allows full control over system sensitivity.
PUG-7, PUG-7A, PUG-7E, PUG-7U – Technical Associates
PUG-7, PUG-7A, PUG-7E, PUG-7U. Univeral Portable Monitor. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid State Probes! Four range survey meter, with adjustable High Voltage, sensitive input, and rugged construction. Add to quote.
The PUG-7N is a complete fast-slow Neutron monitor system. It includes the PUG-7, four-range survey meter with attached detection system: the MO-1 Moderator, and the PNS-20 Probe. The PUG-7N System, or ``Neutron PUG'' detects fast or slow neutrons by means of a thermal Neutron scintillation detector and a moderator. When the detector (PNS-20) is
The PUG-7-D electronics utilizes continuously adjustable regulated high voltage supply 1500V (2,500 volts Optional) to operate GM or scintillation detectors delivering a one millivolt or above pulse. An adjustable discriminator allows full control over system sensitivity.
Pug-7 Survey Meter with PNS-20 Slow Neutron Detector - for sale
The PUG-7 utilizes continuously adjustable regulated high voltage supply 1500V delivering a one millivolt or above pulse. An adjustable discriminator allows full control over system sensitivity. The pulse input is zener diode protected so that probes may be …
PUBG
这个新春,与希腊神话的奇幻世界相遇,解锁多款成长型武器皮肤与全新道具,开启充满惊喜的冒险之旅! 一起来了解一下33.2版本的新功能和优化内容吧! 选购包括各类服装、饰品等在内的多种PUBG商品! PUBG是一款战术竞技射击游戏,100名玩家将会相互角逐。 你需要与对手斗智斗勇,成为最后的玩家。 立即免费游玩!
DESCRIPTION: – Technical Associates
The PUG-7 utilizes continuously adjustable regulated high voltage supply 1500V (2,500 volts on PUG-7A) to operate GM, scintillation gas proportional, BF3, or He3 detector delivering a one millivolt or above pulse. An adjustable discriminator allows full control over system sensitivity.
- 某些结果已被删除