CHAPTER 4 FOUNDATIONS - 2018 INTERNATIONAL RESIDENTIAL CODE …
R403.1.2 Continuous footing in Seismic Design Categories D 0, D 1 and D 2. Exterior walls of buildings located in Seismic Design Categories D 0, D 1 and D 2 shall be supported by continuous solid or fully grouted masonry or concrete footings. Other footing materials or systems shall be designed in accordance with accepted engineering practice.
R403.3 - Digital Codes
R403.3 Frost-protected shallow foundations. For buildings where the monthly mean temperature of the building is maintained at not less than 64°F (18°C), footings are not required to extend below the frost line where protected from frost by insulation in accordance with Figure R403.3 (1) and Table R403.3 (1).
Chapter 4 Foundations: Foundations, New York State ... - UpCodes
See Table R403.3(1) for required dimensions and R-values for vertical and horizontal insulation and minimum footing depth. FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
R4: Supplemental Technical Requirements - United States Access …
Protruding objects shall not reduce the clear width required for pedestrian access routes. Operable parts shall comply with R403. A clear space complying with R404 shall be provided at operable parts. Operable parts shall be placed within one or …
R403.1.3.5.4 - ICC Digital Codes
See the commentary to Section R403.1.3. This comprehensive code compiles all building, plumbing, mechanical, fuel gas and electrical requirements for non-commercial one- and two-family dwellings in one convenient code. The regulations cover dwellings and townhouses up …
Chapter 4 [RE] Residential Energy Efficiency - UpCodes
The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8.
Question 26 - FTC Q&A
R403 was written liberally to allow some creativity for teams in representing their team numbers. There are no rules regarding font stroke width or the specific font to be used, but teams MUST ensure that the team number is easily readable by REFEREES and other FIELD STAFF from at least 12 feet away (per R401 ).
§ 1190.1 Accessibility Guidelines - United States Access Board
These guidelines contain scoping and technical requirements to ensure that pedestrian facilities located in the public right-of-way (including a public right-of-way that forms the boundary of a site or that lies within a site bounded by a property line), are readily accessible to and usable by pedestrians with disabilities.
File : SADC road sign R403.svg - Wikimedia
Original file (SVG file, nominally 450 × 600 pixels, file size: 9 KB) English: Living Street / Woonerf begins. This image is derived from the SADC-RTSM, a convention of the Southern African Development Community designed to provide uniform …
R403.3.5 Duct Testing A duct test shall be performed in accordance with ANSI/RESNET/ICC 380 or ASTM E1554 to determine air leakage and shall be verified by either a post construction test or