Opteon™ XP30 (R-514A) Refrigerant | R-123 Replacement
Opteon™ XP30 (R-514A) refrigerant is a non-ozone depleting, low global warming potential (GWP) hydrofluoroolefin (HFO) based replacement for R-123. It is suitable for new and retrofit systems, offering an optimal balance of properties, including high energy efficiency and environmental sustainability.
While classifi ed as a Group B1 refrigerant, R-514A has a dramatically im- proved exposure limit (6 times higher OEL) compared to R-123, which has been safely used for ≥ 500,000 chiller years of operation for more than 25 years.
R514A - National Refrigerants Ltd
R514A (Opteon™ XP30) – an Azeotrope with zero glide is a low GWP HFO-based refrigerant developed to replace R-123 in low prfessure centrifugal chillers for commercial and industrial applications, suitable for new systems and retrofits.
- [PDF]
Opteon XP30 (R-514A)
Opteon™ XP30 (R-514A) is a low global warming potential (GWP) hydrofluoroolefin (HFO)-based refrigerant developed to replace R-123 in low pressure centrifugal chillers for
Opteon™(欧特昂™)XP30 (R-514A) 制冷剂
Opteon™(欧特昂™)XP30 (R-514A) 制冷剂是一款零臭氧消耗潜值、低全球变暖潜值 (GWP)、基于氢氟烯烃 (HFO) 的 R-123 替代制冷剂。此产品可用于新系统和系统改造,可实现高能源效率和环境可持续性的优化平衡。
R-514A is a design-compatible replacement for R-123 in both engineered retrofit applications and in new production. R-123 (2,2-dichloro-1,1,1-trifluoroethane) is a low-pressure refrigerant primarily applied in centrifugal water-cooled chillers used for industrial air conditioning and climate control of large buildings and complexes.
2020年8月18日 · Opteon™ XP30 (R-514A) Refrigerant Version 9.0 Revision Date: 09/21/2021 SDS Number: 1354360-00045 Date of last issue: 08/18/2020
r-514a HFO azeotropic blend of R-1336mzz (74.7%), (Z)/1130(E) (25.3%) that is for use in low-pressure centrifugal chillers in industrial and commercial appliances.
Refrigerant gases HFO R-514A - Summit Refrigerants
HFO azeotropic blend of R-1336mzz (74.7%), (Z)/1130(E) (25.3%) that is for use in low-pressure centrifugal chillers in industrial and commercial appliances. This low GWP refrigerant is non-flammable, but due to its toxicity classification it has human exposure safety considerations. See SDS for full details.
Trane adopts new low GWP refrigerant R514A - Cooling Post
2016年6月15日 · R514A, developed by Chemours as Opteon XP30, is considered a drop-in replacement for R123. With a GWP of just 2 under AR5, R514A blends the HFO 1336mzz (Z) with trans-1,2-dichloroethene, a gas not previously used in refrigerants. Like R123, R514A has a B1 toxicity classification.