Sheet Metal Installation Guide | Contractor Talk - Professional ...
2015年3月5日 · In our area 30 ga is the thinnest metal you can use for roofing. Because snow sheds off metal, most building departments in lower Michigan allow installation over open rafters with purlins spaced 24 inch. This is a general install manual for homeowners or beginning contractors. It explains the basics of installing metal roofing.
Out of square metal roof install help - Contractor Talk
2012年2月3日 · Thanks for all of the input. I always square to the eave and the metal is 12 inch wide standing seam. I would like to know if anyone recommends doing a square up on the roof when doing the bid to see if I should order longer panels than necessary to accomodate for the out of square condition.
2022年3月23日 · handyman services; driveway or tennis court installation; decorative stone, tile, marble, granite, or terrazzo installation; plastering; stuccoing; caulking; and canvas awning and ornamental iron installation. 02.25.2022tv updated 03.23.2022 . City of Port St. Lucie Building Department Contractor Licensing Division
Metal Roofing Labor Costs - Contractor Talk
2007年3月3日 · What type of metal are you talking about? If standing seam those are dangerously low. If some kind of metal shingle or the cheap imitation standing seam that menards sells, those prices are not at all out of line for easy basic new construction type jobs. If you think you are getting good work at those prices, send those guys my way.
Best drill bit for tile - Contractor Talk
2024年4月14日 · Looking for advice for drilling through ceramic tile, stone tile, etc. I often have to install dispensers in commercial buildings hundreds at a time.
Step Flashing vs. L-Shaped Flashing - Contractor Talk
2009年12月22日 · Hey Knighton, In my humble opinion, it depends on which roof you are installing with what metal. If you are using composition, slate, shakes, wood shingles, etc., and you are talking the pitched run of the roof, then you have to step shingle those applications, as per manufacturer's specs.
Lath or no Lath | Contractor Talk - Professional Construction and ...
2006年11月14日 · 3. 2" is what you need, if wood floor, and using PVC, nothing to screw down yet, cut the pipe 3/4" below the finished floor and glue on the bottom part of the drain, if oatey drain, this method will make it sit on the finished floor with 1/2" or so for the pre-slope mud.
adhesive to bond stainless steel to brick,block and cement
2010年1月16日 · Im seeking a good 10oz tube of glue..Problem is when im replaceing trash chute doors in buildings all i have is brick work to hold the door..Many old units are of cast iron and we have to remove the frames.Leaving nothing but a off square hole..The new doors are designed to screw in from the sides into a sheet metal chute..Pic is below of a door that was installed.
Window flashing & IBC meaning - Contractor Talk
2015年12月30日 · In Calgary, Alberta there are strict compliance rules. you must have flashing over any opening like a window and the same flashing between different cladding or finishes if they do not overlap by 1". the drip flashing over windows etc must be dammed up at each end by bending the metal up one inch. it must also overhang the window 1/2" on either side. there are …
Roof to wall flashing on a bay bump out??? - Contractor Talk
2008年2月23日 · On the horizontal run, a typical roof to wall, aka, apron flashing can be install, which will wind up on top of the last course of shingles. I always use a color coordinated pre-painted finish sheet metal. to either match the shingle color or to match the siding color, whichever would saeem most aestheticaly pleasing.