“TEG talk”: expanding clinical roles for thromboelastography and ...
2020年12月4日 · The kaolin-activated TEG channel (CK) demonstrated a prolonged R time, indicating coagulation factor deficiency. The CK channel also showed a prolonged K time and reduced angle with reduced maximum amplitude (MA) on the functional fibrinogen (CFF) channel, indicating decreased fibrinogen contribution to clot formation.
The TEG 6s Global Hemostasis System is Useful for Coagulation ...
2024年11月1日 · Recently, a new-generation TEG device, the TEG 6s Global Hemostasis System, was introduced. This device offers advantages over TEG 5000, including less frequent calibration requirements, ease of use, and reduced sensitivity to movement. We hypothesized that TEG 6s would enhance coagulation management in SPK.
The TEG 6s Citrated: K, RT, FF Assay Cartridge is used to perform the Citrated Kaolin (CK), Citrated RapidTEG (CRT) and Citrated Functional Fibrinogen (CFF) assays and consists of three...
A comparison between the TEG 6s and TEG 5000 analyzers to
Agreement between the TEG 6s and TEG 5000 systems was examined using citrated kaolin reaction time (CK.R), citrated functional fibrinogen maximum amplitude (CFF.MA), citrated kaolin percent clot lysis at 30 minutes (CK.LY30), citrated RapidTEG maximum amplitude (CRT.MA), and citrated kaolin maximum amplitude (CK.MA) parameters in adults meeting ...
TEG® 6s coagulation testing with a novel heparin neutralization ...
2024年7月27日 · The primary study end points were parameters measured on the TEG 6s device with the HN cartridge: CK-MA, reaction time in the CK assay (time taken for an amplitude of 2 mm to be achieved, or CK-R), CKH-MA, CKH-R, lysis 30 minutes after MA in the CKH assay, CRTH-MA, and CFFH-MA.
Sensitivity and specificity of thromboelastography for ...
2023年7月7日 · The TEG 6s showed superior mortality prediction than the TEG 5000 at lower LY30 levels (≥10%), with likelihood ratios of 8.22 and 2.62 for the TEG 6s and TEG 5000, respectively. Patients with a TEG 6s CK LY30 of 10% or higher were significantly more likely to die, receive cryoprecipitate, receive transfusions, or receive massive transfusion ...
比较 TEG 6s 和 TEG 5000 分析仪以评估创伤患者的凝血功能。
2020年2月1日 · 本研究的目的是验证 TEG 6s 系统可用于创伤患者。 方法 在 12 个美国 I 级和 II 级创伤中心进行方法比较的多中心无创观察研究。 使用柠檬酸高岭土反应时间 (CK.R)、柠檬酸功能性纤维蛋白原最大振幅 (CFF.MA)、柠檬酸高岭土 30 分钟凝块溶解百分比 (CK.LY30)、柠檬酸 RapidTEG 最大值检查 TEG 6s 和 TEG 5000 系统之间的一致性幅度(CRT.MA),和枸橼酸高岭土最大振幅 (CK.MA) 参数满足完整或有限创伤团队标准的成年人。 入院后≤1小时抽血。 一式 …
TEG®6s system measures the contributions of both platelet count …
2019年12月26日 · Furthermore, using LTA TRAP as a confirmatory assay, we have demonstrated that the TEG®6s analyzer can accurately detect platelet function inhibition at levels >68%, below the established cutoff value, and quantify platelet function within a range of 68.4–82% for CK. 69.4–88% for CKH and 69.7–76% for CRT.
TEG® 6s coagulation testing with a novel heparin neutralization ...
Primary end points included TEG parameters in the citrated kaolin (CK), CK with heparinase (CKH), RapidTEG with heparinase (CRTH), and functional fibrinogen with heparinase (CFFH) assays. Results: Evaluable data were contributed by 164 volunteers (48.8% female; 62% White/Caucasian).
The TEG 6s System: System Description and Protocol for
2023年5月20日 · CK (citrated kaolin) assay results are generated by kaolin (intrinsic pathway activation). For the CK assay, kaolin-activated test methods are used to reduce variability and to reduce the running time of a native blood sample. This test reports R, …