TMC报错相关 | FLY Docs - Klipper
TMC ‘extruder’ reports error: DRV_STATUS: 601f1000 s2vsa=1(ShortToSupply_A!) csactual=31 ola=1(OpenLoad_A!) olb=1(OpenLoad_B!)) . 报错详情. 暂无图片; 报错原因. 检查驱动器电流不正确; 主要解决方法. 检查步进电机AB两组线圈阻值是否一致; 检查步进电机或者部件电机内部的电线 …
[Issue] TMC 'stepper_z' reports error: DRV_STATUS: 801100a0 …
2021年7月7日 · Update: now my extruder makes a buzzing/clicking noise (not the type you get from skipping stepps) when trying to move. What is going on?! restarting klipper fixed this …
TMC: DRV_STATUS: 40110060 s2vsb=1(LowSideShort_B!) ola=1 ... - Klipper
2021年7月9日 · The root cause of your issue is a “TMC reports error” problem - the cause and common fixes are documented at: https://www.klipper3d.org/TMC_Drivers.html#why-did-i-get-a-tmc-reports-error–error. You may also wish to try completely disabling stealthchop mode as that can often cause subtle issues like this.
Error ShortToSupply_A! on extruder - General Discussion - Klipper
2023年10月17日 · TMC ‘extruder’ reports error: DRV_STATUS: 601f1000 s2vsa=1 (ShortToSupply_A!) csactual=31 ola=1 (OpenLoad_A!) olb=1 (OpenLoad_B!) I’ve checked this page where it said it could be the wiring, stepper driver, or extruder and so I’ve done the following, but still get the same error every time.
TMC Extruder Error - VORON Design
2023年4月28日 · From what I can tell from the "TMC2209 Datasheet" s2vsb=1(ShortToSupply_B!) indicates low side short phase B and ola/olb indicates a open load phase A/B but that could be a false detection. I pulled the driver from the board to check connection but that seems good.
TMC 'stepper_z' reports error: DRV_STATUS: 001900d0 s2vsa=1
2022年8月17日 · Right after fixing my previous issue, I ran into the next. For any axis I try to move, buzz or home I get error (s). The stepper very shortly does get power (like, half a second), and then right away klipper shuts down the MCU. Last time I just had some lines wrong, I hope its the same case this time.. Things that may perhaps be of use:
TMC Error Related | FLY Docs
TMC ‘extruder’ reports error: DRV_STATUS: 601f1000 s2vsa=1(ShortToSupply_A!) csactual=31 ola=1(OpenLoad_A!) olb=1(OpenLoad_B!) . Error Details. No image available; Error Cause. Incorrect driver current check; Main Solution Method. Check if the resistance values of the two coil groups A and B of the stepper motor are consistent
VORON2 开始接线 – 凌顺实验室 - LingShunLab.com
2022年11月14日 · 本文写关于VORON2 的接线详细以及注意事项。 连接打印机电子设备时,您将使用电压220V/120V的交流电接线,请在触摸任何电线或端子之前,务必仔细检查以确保您的打印机已拔下电源,并且确保电路或器件中的电容器已放电完全(例如,如果没有负载的话,需要等待1分钟以上,可以观察开关电源的绿色工作灯是否熄灭,前提是开关电源有这个灯,一般都会有)。 此处提出的建议通常是出于防止火灾的充分谨慎。 接线的时候,要搞清楚正负极的概念 …
TMC 驱动器 - Klipper 文档
TMC驱动程序的 interpolate 设置可以减少打印机运动的噪音,但代价是引入一个小的系统位置误差。这个系统性的位置误差是由驱动器在执行Klipper发送的 "步骤 "时的延迟造成的。
TMC 'extruder' reports error: DRV_STATUS: c00e0090 on TMC ... - GitHub
2021年3月13日 · TMC 'extruder' reports error: DRV_STATUS: c00e0090 s2vsa=1(LowSideShort_A!) olb=1(OpenLoad_B!) CS_ACTUAL=14 stealth=1 stst=1 Once the underlying issue is corrected, use the "FIRMWARE_RESTART" command to reset the firmware, reload the config, and restart the host software.