How to properly extend the TPR Pipe on a water heater
2017年9月26日 · Place one wrench on the TPR valve, to prevent the valve from moving (a pipe wrench works well). Place the other wrench on the drain tube. Use the first wrench to hold the TPR in place, when you use the other to unscrew the drain pipe. Cut the new pipe to length. Apply PTFE tape (or your preferred pipe dope) to the threads of the pipe.
TPR Drain pipe - General Inspection Discussion - InterNACHI®️ …
2008年3月7日 · The following are thirteen requirements for a discharge pipe serving a TPR valve: 1) The pipe should not be directly connected to the drainage system; 2) The pipe should discharge through an air gap located in the same room as the water heater; 3) The pipe should be constructed of materials tested, rated, and approved for such use; 4) The pipe ...
Code Ref for TPR valve piping? - InterNACHI®️ Forum
2006年9月20日 · IRC P2904.5 Water-distribution pipe. Water-distribution piping within dwelling units shall conform to NSF 61 and shall conform to one of the standards listed in Table P2904.5. All hot-water-distribution pipe and tubing shall have a minimum pressure rating of 100 psi at 180°F (689 kPa at 82°C).
TPR Discharge Pipe Piped Correctly? - InterNACHI®️ Forum
2020年9月14日 · TPR discharge configured with flex water tube just laying in a plastic bucket. Plastic flex hose connected to a sump pump. The plastic hose went up thru the ceiling - thru the attic - terminated thru the soffit (12 feet in the air).
TPR Valve Discharge pipe - Plumbing Inspections
2016年9月2日 · Good Afternoon, Been coming across several TPR discharge pipes that are very close, if not touching, the bottom of a water heater drip pan. What is the minimum distance from the bottom of the drip pan? Should’t there be some air gap? I understand the 6 inch rule for discharging to a waste receptacle but how close can the pipe be …
TPR Discharge Pipe Routing - InterNACHI®️ Forum
2024年4月26日 · To me #6 in that list is the fall safe needed to detect a problem with the TPR valve. In my area hard water will leave deposits on any valve or leaking pipe joint. The hidden deposits inside a leaking TPR valve could prevent it from working. I always make a point to tell clients water should NEVER drip out of the pipe, if it does call a plumber.
TPR Discharge piping - InterNACHI®️ Forum
2022年8月30日 · Below copied in part from: TPR Relief Valve Discharge Tube Codes & Hazards Installation, inspection, & specifications for discharge tubes on TPR valves used on boilers & water heaters TPR Valve Discharge Tube Materials : the drain line material requirements vary by jurisdiction; some areas permit both plastic as well as copper or galvanized ...
Is this an appropriate TPR valve diversion? - InterNACHI®️ Forum
2020年6月4日 · The washer was removed but clearly previous owner was wedging it in there. I told my client having that washer drain pipe pinched in there together was an issue. Funny thing is this was the second house I inspected for him that had a tpr drain line issue. He backed out of the other house but it was a newer water tank with no drain line at all.
TPR Flexible Drain Line - Plumbing Inspections - InterNACHI®️ …
2015年8月27日 · Thanks Charles! I just found similar: 608.5 Drains. Relief valves located inside a building shall be provided with a drain, not smaller than the relief valve outlet, of galvanized steel, hard drawn copper piping and fittings, CPVC, or listed relief valve drain tube with fittings which will not reduce the internal bore of the pipe or tubing (straight lengths as opposed to coils) and shall ...
TPR Valve Discharge Pipe missing Florida 4-point
2023年2月2日 · What do you say about TPR valve pipes that have 90 installed directly after TPR valve. To me seems to be an obstruction. there are 90s all the time on water heaters. Many water heaters have the TPR on the top of the tank, so it has to 90 down to the ground.