2009年11月7日 · HI all, I have a 2,000 HP motor to be procured and designed to be operating outdoors exposed to summer and winter time conditions. Outdoor ambient can be as cold as -45 Deg C (Canada). I initially specified TEFC as these are vertical motors and TEFC would offer more compactness against TEAAC...
TEFC vs TEAAC - Electric motors & generators engineering - Eng …
2011年2月16日 · Hi, I'm preparing data sheets for some big pumps, medium voltage (4160V), and motors between 200 and 1000 HP. I have my doubts about requesting all motors with a TEFC enclosure, or maybe a TEAAC enclosure could be an option for the big ones. Can somebody give me some recommendations when to...
What is better WPII or TEAAC enclosures for EM - Eng-Tips
2001年12月19日 · RE: What is better WPII or TEAAC enclosures for EM electricpete (Electrical) 19 Dec 01 17:50 A totally enclosed motor will provide better protection from contaminants and moisture in the environment, but may cost more.
TEAAC (4160 VAC) motor protection. - Eng-Tips
2019年9月23日 · In our plant we have medium voltage motor (4160 VAC) TEAAC, 2611KW which is the main motor and it is cooling by low voltage (480 VAC) blower motor. The way how we run these motors as below: -We have a logic to run the blower motor first then the main motor (2611KW) will run and if the blower motor trip or fail for any reason the main motor will ...
What is better WPII or TEAAC enclosures for EM - Eng-Tips
2001年12月19日 · Dear Experts: Would you gime some tips for selecction of enclosures for an electrical motor. Is right to select TEAAC instead of WPII enclosures, because TEAAC is better than WPII. Thanks for your help Leonardo27
TEAAC Motors - Electric motors & generators engineering - Eng-Tips
2008年1月31日 · TEAAC Motors Thread starter magneticted; Start date Jan 31, 2008; Status Not open for further replies. ...
4160 vs 13200v Motor Cost & Size - Eng-Tips
2005年5月6日 · Can anyone give a brief explanation as to why there is such a price difference between a 4160v vs 13.2kv TEAAC 3600 rpm 5000hp Induction Motor? Also the Frame size is the same. What's the driving force which accounts for $500k vs $700k? Physical components which would account for this difference? Thanks in advance.
Air cooled v Water Cooled Motor - Electric motors ... - Eng-Tips
2003年3月12日 · Pro's & Con's in desert environments: TEAAC versus TEWAC TEWAC (water cooled) - Noise level is substantially lower than TEAAC design - typical cooling water temp is 25C, but have seen designs up to 35C using two or three radiators - Radiators can be offer with double walled piping. Need water analysis to determine best cooling tube material.
Motor stator failure - Mechanical engineering general discussion
2010年10月8日 · We decided to remove the stator and found the squirrel cage broken (se attachment "May2008 failure") the motor was a GE 591 HP, Model: 5K82094062501, Poles: 2, Voltage: 4000V, Frequency: 60 Hz, Phase: 3, Frame 8209S, Enclosure: TEAAC.
IEC - Method of cooling -Nomenclature - help 2 - Eng-Tips
2004年3月7日 · A full desciption of the IEC cooling codes can be found in IEC document 60034-6 . IC 616 translates to what you will know as a TEAAC machine with a separate motor driven fan to circulate the external cooling air , whereas for code IC 611 the external cooling air is circulated by a shaft mounted fan.