Assembly Detail - UL U419 - USG
UL U419. Interior Partition - Steel Stud (Non-Load-Bearing) Fire Rating: 1 hours: System STC: 49 System Thickness: 4.875 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U419 on the UL website. More; Assembly Construction. Assembly Construction. Layer 1 - Gypsum Panel:
2024年3月15日 · Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
zFire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
Fire-RatedFire-resistance ratings have long been used by UL, ASTM and building codes to measure the performance of various constructions for fire containment purposes. As applied to elements of buildings, the fire-resistance rating classifies the ability of an assembly
Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field.
UL Design U419 - 1, 2, 3 or 4 Hour Wall Assembly - BuildSite
Get quotes from distributors near you. Find UL Design U419 - 1, 2, 3 or 4 Hour Wall Assembly with a complete list of qualifying products on BuildSite. Download product data and MSDS here.
Assembly Detail - UL U419 - USG
Interior Partition - Steel Stud (Non-Load-Bearing)
UL Wall Assemblies with STC and Fire Ratings - Knauf Insulation …
Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. Find resources and details for UL rated wall systems with the required STC and fire ratings for your project.
Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered Certified.
Fire Resistance Products, Systems and Designs | UL Solutions
2020年9月16日 · We provide training, advisory, testing, Verification, inspection and certification services for the fire resistance industry to help you get compliant products to the market faster.
- 某些结果已被删除