Urinal - The Building Code Forum
2024年3月27日 · Single-user unisex facilities shall include a urinal in food service establishments or any establishment that sells alcoholic beverages for on-site consumption. A single user facility with a WC and Urinal installed will only count as one …
Urinal Requirement - The Building Code Forum
2021年4月12日 · SH225 is correct single use toilets shall be "all Gender". If you want the restrooms to be gender specific, you need two fixtures. (two toilets in the Women's, and a Toilet and Urinal in Men's) A "B" occupancy also has a minimum requirement of a urinal, per 2019 CPC TABLE 422.1. Alcohol Beverage Control also has a urinal requirement.
Are Urinals Required in Unisex Restrooms? - The Building Code …
2023年11月13日 · For utmost privacy we recommend modesty screens between each urinal, and floor-to-ceiling walls and doors for all stalls. The third option affords all users the greatest privacy, but multiple toilet rooms with locking doors can make the project more expensive.
Urinal required in a single occupancy toilet for "B" occupancy?
2011年8月16日 · We have a plan checker that is insisting that because the California Plumbing Code table 422.1 indicates that a urinal is required for 1-100 men for a B occupancy that even when a single room occupancy toilet room is allowed to serve both employees and customers that this room also is required to have a urinal.
Urinal flushometer [Vacuum Breaker] - The Building Code Forum
2013年1月6日 · Re: Urinal flushometer [Vacuum Breaker] Thanks for the replies. It's a solid slab of granite on the wall, so the only real option would be to go back to the original urinal as opposed to raising the water height. It's a shame as the urinals he got are really amazing looking, and the original ones are nothing special.
Urinals in Single User Restrooms | The Building Code Forum
2009年10月25日 · I have read many items on this including the BU_17-01-01.pdf from the DSA, HSC 118600 on Single User Restrooms, an Iapmo interpretation and we have not found where the text allows an elimination of the urinal. Female water closets must equal W/C and urinals required in a men's room, but this does not apply when it is a single user facility in ...
Minimum Required Size of Non-ADA Toilet Stall
2009年11月25日 · 405.3.1 Water closets' date=' urinals, lavatories and bidets. [/b']A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction, or closer than 30 inches (762 mm) center to center between adjacent fixtures. There shall be not less than a 21 ...
Bathroom stall door and partition height - The Building Code Forum
2009年10月17日 · urinal measured from the finished backwall surface, whichever is greater. Exceptions: 1. Urinal partitions shall not be required in a singleoccupant or family or assisted-use toilet room with a lockable door. 2. Toilet rooms located in child day care facilities and containing two or more urinals shall be permitted to have one urinal without ...
Urinal Vacuum Breakers - The Building Code Forum
2010年9月14日 · 2009 UPC. We have a plumbing contractor proposing to install a 90 deg turn metering push button valve on a urinal. The valve is a Pasco, part # 21810. This valve does not appear to have a vacuum breaker on it. Has anyone ever seen this valve installed? I looked into the 2006 IPC to see how it...
Non-ADA Toilet Stall Dimensions - The Building Code Forum
2016年1月18日 · IPC 405.3.1 Water closets, urinals, lavatories and bidets. A water closet, urinal, lavatory or bidet shall not be set closer than 15 inches (381 mm) from its center to any side wall, partition, vanity or other obstruction, or closer than 30 inches (762 mm) center to center between adjacent fixtures.