CTXA Hip—An Extension of Classical DXA Measurements Using …
2014年3月17日 · CTXA Hip uses 3D QCT volume data sets to generate bone projection images that visually look like those generated by DXA. CTXA Hip exploits the anatomical detail in the 3D QCT data set to segment bone from surrounding tissues rather than relying on the dual-energy imaging method of DXA.
<br>CTXA 髋关节——使用定量 CT 的经典 DXA 测量的延伸 …
2014年3月17日 · 我们将商业定量 CT (QCT) BMD 分析系统“CTXA Hip”(提供股骨近端的临床数据)的 BMD 结果与 DXA 结果进行了比较。 我们还使用 CTXA 髋关节来确定皮质和小梁对总 BMD 的贡献。
Mindways Software - QCT
CTXA (Computed Tomography X-Ray Absorptiometry) enables you to produce DXA-equivalent hip measurements— including for usage with WHO criteria for fracture-risk assessment—from a CT volumetric data set.
QCT骨密度测量体模软件检测法和DXA测量的CTXA髋关节延伸
2021年4月14日 · CTXA髋关节提供了与传统DXA基本相同的临床信息,并且还提供了在单独的皮质和小梁骨隔间中BMD的估计,这可用于骨强度的评估。 介绍. 骨质疏松症是一个重大的公共卫生问题。 据估计,美国高达50%的女性和20%的男性在其一生中存在骨质疏松相关骨折的风险(1)。 骨密度(BMD)估计可用于测试骨质疏松性骨折风险,并作出有关药物治疗开始的决定。 根据国际社会的Clinical Densitometry(ISCD)(2)和国家骨质疏松基金会(NoF)〔3〕的 …
QCT of the femur: Comparison between QCTPro CTXA and MIAF …
2019年3月1日 · In this study we compared two analysis software options, QCTPro CTXA and MIAF-Femur, using CT scans of the semi-anthropometric European Proximal Femur Phantom (EPFP) and in vivo data from 130 Chinese elderly men and women aged 60–80 years.
CTXA hip--an extension of classical DXA measurements using
2014年3月17日 · We have compared BMD results from a commercial Quantitative CT (QCT) BMD analysis system, "CTXA Hip", which provides clinical data for the proximal femur, to results from DXA. We have also used CTXA Hip to determine cortical and trabecular contributions to total BMD. Sixty-nine patients were scanned using 3D QCT and DXA.
CTXA Hip—An Extension of Classical DXA Measurements Using QCT
2012年10月1日 · CTXA Hip provides substantially the same clinical information as conventional DXA, and in addition provides estimates of volume-derived parameters which may be useful in evaluation of bone strength.
QCT定量CT骨密度分析软件与 DXA 测量近段股骨面积骨密度及 T
2024年9月22日 · CTXA 扫描需要的射线剂量高于 DXA,但 CTXA 可以和临床常规髋关节 CT扫描结合起来,从而不增加额外射线剂量,并且CTXA 能广泛的应用于髋关节骨折患者的诊疗。
Use of a real time PCR assay for detection of the ctxA gene of …
We report the development of a real time PCR (qPCR) assay to detect the gene encoding cholera toxin, ctxA, found in toxigenic V. cholerae strains. This assay was tested against DNA isolated from soil samples collected from diverse locations in the US, a panel of eukaryotic DNA from various sources, and prokaryotic DNA from closely related and ...
定量CT QCT骨密度测量体膜软件测量髋关节骨密度的重复性与DXA …
2021年2月28日 · 成都华西华科研究所研发QCT探讨定量CT (QCT骨密度测量体膜软件)髋关节骨密度(BMD)测量重复性及与双能X线骨密度测定仪 (DXA)测量的一致性。 方法随机抽取28名(男10例,女18例)老年受试者(男性>60岁,女性>50岁), 并分别采用QCT骨密度测量体膜软件与DXA测量髋关节骨密度。 收集左侧髋关节QCT骨密度测量体膜软件扫描CT原始数据,分别由3名操作者各测量 1次,其中1名操作者在不同时间重复测量3次,用于评价QCT骨密度测量体膜软件 …