What does "1 Gang", "2 Gang", and so forth mean when talking …
2017年1月25日 · Thanks for the clarification. Does a 2-gang box in the UK correspond to a 2-gang box in the US? A brief google seems to me that a 2-gang UK box is like roughly 1.5x a 1 …
Wiring 4 gang box - Home Improvement Stack Exchange
2018年1月12日 · @Harper the problem is not figuring out what wire power which light it's the wires beneath the box coming from the breaker. 2 out of the 3 carry power to the gang box …
electrical - Wiring problem on 4 gang metal light switch - Home ...
2019年12月30日 · If you post the size of your box (usually marked in cubic inches inside the box) and a new diagram once you've removed the two left-most devices, we can confirm whether …
How to deal with large 4-gang switch boxes and the need to wire ...
However there are a number of large 4-gang switch boxes and I'm not sure what to do about the many wires which are brought together in a wire nut. In one switch there are 5 NM power lines …
wiring - Grounding my 4 gang metal electrical box - Home …
I have a 4 gang metal electrical box with a receptacle, a fan switch, a light switch and a timer for a towel warmer. The honeywell timer does not require to be grounded. For the receptacle i …
Smart switch in a 4 gang box - Home Improvement Stack Exchange
2021年12月18日 · One cable going out for each switch = 4 cables; One cable going on to the next location; That would be 6 black hot/switched hot and 6 white/neutral, as follows for "dumb" …
electrical - Convert 4 gang to 3 gang switch box - Home …
2019年8月12日 · Unless you are planning to do some patching and painting I am afraid you are stuck with a 4G box. If you want to remove the switch because its just irritating you can use a …
Replacing a 4-gang standard switches with smart Kasa switches
2023年11月27日 · I am trying to replace a 4-gang standard switches with Kasa smart switches. How do I connect all the neutral white wires from the switches to the white neutral bundles in …
Finding a good smart switch 3 or 4 gang but the box is sized for 4 ...
2021年9月18日 · So the biggest issue here is the heater. Most 4 gang don' support more than 10A. There's no way the other 3 things are going to exceed 10a. The heater could draw 12.5a …
electrical - Reversed hot/neutral in properly wired circuit - Home ...
2025年3月16日 · For the new leg, I'm taking current from the 4 gang box, running it a 2 gang outlet box, a switch and a single gang outlet. All circuits on the new leg measure as "Reversed …