Remove EDF Fan Lip - RC Groups
2022年7月13日 · I am doing a 70mm edf fan to 90mm edf fan conversion in a jet. But inorder to make it fit, I will need to grind off the lip of the edf fan unit. Is this an absolutely wrong thing to do, as in it would cripple the plan badly ?
Intake Lips - TURBINES RC
Intake Lip for Wemotec 90mm EDF Midi Fan (classic & evo) or Ejets Jetfan 90 and other 90mm EDF units.
VF-390 STANDARD - VasyFan
With this new EDF of very particular dimensions, we intend to reach the customer who no longer uses it only at RC level but above all on VTOL aircraft and other special applications. The design of this new EDF system is based on the technological know-how accumulated thanks to the creation of numerous prototypes thoroughly tested in recent years.
Purpose of an intake lip on EDF's? - RC Groups
2013年3月27日 · The lip allows the incomming air to flow around the edge of the fan without turbulating..with out the lip the air will trip over the edge and cause a turbulant wake which will make the fan think the intake is smaller diameter than it really is.
Dr. Mad Thrust 90mm 12 Blade Alloy EDF Tests - RC Groups
2014年8月12日 · Since most of the Dr. Mad Thrust 90mm 12 Blade EDFs now use housings and the one piece RCLander 12B rotor which we now know is made by Haoye, I open this thread to discuss these fans and their performance. Having used the the 10S, 1000kv version for quite a while in the Taft Viper, I saw that a new 12S, 700kv version was out.
EDF Ducting Design : r/radiocontrol - Reddit
2020年8月24日 · The sharp edge around the EDF intake causes turbulence and reduced performance. You want a nice rounded intake lip like this , with a lip radius of at least 6% of the fan diameter. This will improve static thrust by a large amount.
70mm EDF - JP HOBBY Europe
This is an Open Duct inlet lip especially for the use in the JP Hobby 70mm and other EDF of same diameter.
EDF Ducted Fan FD Model 70mm 12 blades + 6S Motor 2300KV
EDF Ducted Fan FD Model 70mm 12 blades + 6S Motor 2300KV Features. Efficiency, robustness, performance and good balance, FD model turbines are offered at an attractive price; Big air volume; Sound realistic
EDF Ducted Fan JP Hobby 90mm + 12s Motor 1080KV (CCW)
100% CNC aluminium JP Hobby EDF unit (shroud and rotor) for 12s. CAUTION: JP Hobby EDF are fitted with specific 12-pole motors compatible with JP Hobby brushless controllers offered as "Must have Accessories" on this page. Only the use of these controllers validates your warranty and ensures the correct functioning of the EDF.
Ducted Fan Design Rules of Thumb - RC Groups
2014年11月9日 · The rounded intake lip on the EDF-55 is for designs that doesn't use internal ducting. As for intake and exhaust area, this is based on the Fan Swept Area (FSA). This is the area that the rotor/prop occupies in the duct/shroud while spinning, minus the area taken up by the hub/spinner.