
Opteon™ XP30 (R-514A) Refrigerant | R-123 Replacement
Opteon™ XP30 (R-514A) refrigerant is a non-ozone depleting, low global warming potential (GWP) hydrofluoroolefin (HFO) based replacement for R-123. It is suitable for new and retrofit systems, offering an optimal balance of properties, including high energy efficiency and environmental sustainability.
R514A - National Refrigerants Ltd
R514A (Opteon™ XP30) – an Azeotrope with zero glide is a low GWP HFO-based refrigerant developed to replace R-123 in low prfessure centrifugal chillers for commercial and industrial applications, suitable for new systems and retrofits. Although non-flammable it has been designated B1 and is at the higher end of Ashrae’s toxicity classification.
R514A Calibration Gas
Certified R514A Calibration Gas in 17L bottles with various concentrations for calibrating and testing gas detectors. All gas is NIST certified and traceable.
GASCO R-514A Calibration Test Gas Balance Nitrogen - Cal Gas …
GASCO R-514A Refrigerant Calibration Gas 1000 PPM Balance Nitrogen in a 116 Liter Aluminum Factory Refillable Cylinder
Gas lạnh opteon XP30 R-514A - Vật Tư Điện Lạnh, Điện Công ...
Opteon ™ XP30 (R-514A) là một chất làm lạnh không phải là ozone, với chỉ số nóng lên toàn cầu (GWP) thấp, và còn là hydrofluoro-olefin (HFO) thay thế cho R-123 trong máy làm lạnh ly tâm áp suất thấp.
GASCO R-514A Refrigerant Calibration Gas 1000 PPM Balance …
R-514A Refrigerant Calibration Gas in Nitrogen contained in a 58 Liter Aluminum Disposable Cylinder, For Use with Any and All Gas Detectors, Cylinder connection C-10, Calibration Certificate NIST, Made in the USA, Calibration Refrigerant Gas is intended for use in Calibrating Refrigerant Gas Detection Equipment Only.
- [PDF]
Opteon XP30 (R-514A)
Opteon™ XP30 (R-514A) is a low global warming potential (GWP) hydrofluoroolefin (HFO)-based refrigerant developed to replace R-123 in low pressure centrifugal chillers for
of low-pressure refrigerants, i.e. R-514A, many of the same procedures may be applied for the safe handling of all refrigerants. Because these are updated guidelines, procedures for the service technician’s conservation and safe handling of low-pressure refrigerants in Trane®chillers will differ from guidelines previously published.
Gas Opteon™ XP30 (R-514A) | Mạnh Tuấn - Manh Tuan
Opteon ™ XP30 (R-514A) là một chất làm lạnh không phải là ozone, với chỉ số nóng lên toàn cầu (GWP) thấp, và còn là hydrofluoro-olefin (HFO) thay thế cho R-123 trong máy làm lạnh ly tâm áp suất thấp.
This low GWP refrigerant is non-flammable, but due to its toxicity classification it has human exposure safety considerations. See SDS for full details. Type of replacement: New equipment and retrofit for low pressure R-123 systems.
- 某些结果已被删除