The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing. SSA 500, stainless steel angles option for GTEM 500, recommended for countries with high humidity like Thailand, Malaysia, Philippines... The door side and the country version of the single phase AC socket needs to be selected.
GTEM 500 - AMETEK CTS
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with …
GTEM 500 Radiated Emission and Immunity Testing for IEC/EN …
The GTEM 500 cell is a GTEM waveguide with the upper frequency limit extended to the GHz range. It is a low-cost alternative measurement facility for both radiated emission and immunity measurements. It is included in the recently published standated IEC/EN 61000-4-20 "Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.
EMC GTEM–500 Gtem Cell For emission and immunity testing according to IEC 61000-4-20 Theory of operation GTEM-cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for electromagnetic compatibility measurements, as …
Teseq GTEM 500 GTEM Cell for Emissions and Immunity Testing
A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with …
SSA 500, stainless steel angles option for GTEM 500, recommended for countries with high humidity like Thailand, Malaysia, Philippines… SHD 2, additional door, clear opening of 44 cm x 38 cm
Gtem Cells » GTEM 500F – GTEM550F
The GTEM cell is, in principle, a tapered coaxial line (offset septum plate), which is terminated by a hybrid combination of discrete resistors and RF absorber to achieve a 50 Ohm broadband match. It is applied for the measure of Radiation emissions and radiofrequency field-immunity test.
Equipment - GTEM500 - CPI
Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. The GTEM 500 operating range 1 MHZ — 20 GHz. It has a maximum input power range of 500 W, Peak 2 KW .
GTEM Cells | EM Test | Teseq - AMETEK CTS
The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing. XYZ Manipulators are ideal for easily rotating the EUT into the three required orthogonal axis positions. The manual versions (MPH) are installed inside the cell while the remote controlled versions (MPC) have a motor und...
TESEQ GTEM 500 GTEM Cell for Emissions and Immunity Testing
The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing. Features. Emissions and immunity testing in a single, shielded environment ; Meets basic standard: IEC/EN 61000-4-20; Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables