
DRGEM GXR-C Series - C32/C40/C52 | Innova Healthcare
DRGEM GXR-C Series – C32/C40/C52 Only 3kVA line power capacity is enough for X-ray generation up to 52kW output ! SKU: INN009 Category: X-Ray Generators Tag: DRGEM
GXR Diagnostic X-ray Brand: DRGEM Corporation, Korea - Dmebd
GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient.
GXR-C32 32kW 640mA at 81kV 500mA at 104kV 400mA at 130kV 320mA at 150kV (Optional) GXR-C52 52kW 500mA at 80kV 400mA at 100kV 320mA at 125kV 250mA at 150kV (Optional) GXR-C40 Output Rating 40kW Linearity Coefficient of Linearity < 0.01 : CL = (X1-X2)/(X1+X2), where X is mR/mAs 230VAC, 1A, 230W (PBT-4) External …
A large tabletop with extended travel enables all radiography studies with minimal patient movement, and supporting patient weight up to 300kg. Fully flat tabletop without a frame on the edge makes cleanliness and odors free.
The GXR-SD Series is a diagnostic digital radiography system that provides reliable high quality digital radiographic images with a reduced dose.
GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs. GXR X-ray system is designed to provide convenience to operator and comfort to patient.
GXR X-ray system is equipped with a high frequency X-ray generator which consistently produces high quality radiograph in favor of high quality X-ray output with a very small kV ripple and accurate mA and mAs.
GXR-C SERIES Capacitor assisted High Frequency X-ray Generator Only 3kVA line power capacity is enough for X-ray generation up to 52kW output ! Features Option Excellent Performance and Stability Full Auto mA calibration, kV calibration, kV & mA feedback waveform display and analysis
FUJIFILM FDR CLINICA - Radiology Imaging Solutions
New features improve workflow and patient experience. Dual-reference Rotation. Both top- and center-reference rotation are available in our rotating tray, with automatic connection to the detector. The detector can be rotated while mounted in the tray with no need to remove and remount, greatly reducing handling. Tilting Wall Stand.
Generador asistido por capacitores GXR-C40 – RTR Medical
Excelente rendimiento y estabilidad, 40 kW, 40-125kV, 10-500 mA, 0.001-10 sec. Calibración automática completa de mA, calibración kV, visualización y análisis de la forma de onda de retroalimentación kV y mA. La calibración adaptativa de mA compensa automáticamente el envejecimiento del filamento.
- 某些结果已被删除