2020年8月13日 · Controllers Active Posts; MicroSmart FC6A A powerful micro PLC with the features of a PAC making it an ideal fit for demanding applications.
Search Results | the - support.us.idec.com
The IDEC relays and bases are NOT required to have SCCR ratings as defined by UL508A standards. This requirement would only apply to circuit breakers, overloads, disconnects, and fuse block combinations. The IDEC relays and bases are not affected by this regulation and therefore there are no ratings for us to provide
View this step-by-step tutorial on how to configure Mod… - IDEC
If you want to have this box check, then in "Communication Driver Extension" tab make sure you put in the Client IP address (in this case 10.9.75.102) edited by [email protected] on 7/15/2014 Expand Post
Search Results | the - IDEC
The IDEC relays and bases are NOT required to have SCCR ratings as defined by UL508A standards. This requirement would only apply to circuit breakers, overloads, disconnects, and fuse block combinations. The IDEC relays and bases are not affected by this regulation and therefore there are no ratings for us to provide
Public FAQs - IDEC
It is up to you, based on the needs of the application. For example, a 0-10V signal coming into the FC6A-J4CN1 card, which has 16 bits of resolution.
You can save a program directly from your PC/laptop ont… - IDEC
2020年2月13日 · You can save a program directly from your PC/laptop onto a micro SD memory card in the FL1F SmartRelay using file name and type as follow: File name: LOGO_U_P (Don't use different name) Files of Type: Binary dump (.*bin)
Tutorial - Creating Web Page - No HTML Required! - IDEC
The instruction indicates that the web page can link to the WindLDR simulation function. However, I have only received the message "Failed to communicate with WindLDR.
Product FAQ: How do I use the value of an analog input or a data …
The 0-10VDC (or 4-20mA) signal will be converted into values of 0-4095 or 0-50,000 depend on the analog card being used and stored in a special data register (i.e. D760).
BACnet/IP protocol is now supported in the FC6A Plus CP…
BACnet/IP protocol is now supported in the FC6A Plus CPU. Just download the latest version of AO 3.12.00 and upgrade the firmware.
What kind of the data format can I use for the data register values ...
You can choose desired format from the following 7 different formats: - One word, signed decimal number - One word, unsigned decimal number - One word, a hexadecimal number - Two words, signed decimal number - Two words, unsigned decimal number - Two words, hexadecimal number - Two words, float number (IEEE754 compliant, 7 digits)