Issue: 1.0 LOSS PREVENTION STANDARD LPS® 1655 June 2015 REQUIREMENTS AND TEST METHODS FOR THE LPCB APPROVAL AND LISTING OF PERSONAL PROTECTION WATERMIST SYSTEMS Page 5 of 21 1 SCOPE This document specifies the requirements and test methods for LPCB approval and listing of local application watermist systems for use as Personal Protection
BRE expert personal protection systems - BRE Group
LPS 1655 covers the requirements and test methods for the LPCB approval of personal protection watermist systems. LPS 1655 contains, system design requirements, including minimum levels of performance and functionality, system manual and installer requirements, fire test protocols, maintenance arrangements and covers component examination and ...
BRE Global Introduces the First Watermist Standard for the …
2015年12月2日 · Find out how LPS 1655, the latest Loss Prevention Standard from BRE Global, defines requirements and test methods for LPCB third-party approval and listing of Personal Protection Watermist Systems.
BRE Global’s new standard puts spotlight on fire risks to …
2016年9月29日 · LPS 1655*, the latest Loss Prevention Standard from BRE Global, introduces the UK’s first fire performance benchmark for Personal Protection System (PPS) equipment. Developed in consultation with industry stakeholders, LPS 1655 defines requirements and test methods for LPCB third party approval and listing of Personal Protection Watermist Systems.
LPS 1655: Issue 1.0 Requirements and test methods for the LPCB approval and listing of personal protection watermist systems. This certificate and appendix is maintained and held in force through regular surveillance activities and subject to the corresponding ISO 9001 Certificate being maintained. Sarah Colwell 16 September 2016 16 September 2016
Personal Protection Systems - Prevent Systems
Accredited Certification to LPS 1655; Fully portable, self-contained system; Simple keypad operations; Monitored smoke alarms for rapid detection; Fire control within minutes of discharge; 3 day battery back-up in case of mains failure; Wireless auto dialer for activation alerts to your preferred nominee; Minimal damage to property when activated
BRE Global’s new standard puts spotlight on fire risks to …
2015年12月10日 · LPS 1655*, the latest Loss Prevention Standard from BRE Global, introduces the UK’s first fire performance benchmark for Personal Protection System (PPS) equipment. Developed in consultation with industry stakeholders, LPS 1655 defines requirements and test methods for LPCB third party approval and listing of Personal Protection Watermist Systems. PPS are local application fire suppression ...
For example LPS 1655 “Requirements and test methods for LPCB approval and listing of personal protection watermist systems”. Where the risk assessment has identified that the principal fire hazard is not confined to a specific area. The listed examples are illustrative.
First BRE Global-certificated portable watermist system …
2016年10月20日 · Surefire has launched the first portable watermist system to achieve third-party certification to LPS 1655, BRE Global’s dedicated fire performance standard for personal protection systems (PPS). Called UltraGuard the unit is a domestic fire suppression system designed to protect vulnerable people – such as the elderly or disabled – from ...
UltraGuard: a portable sprinkler mist system - Surefire Services
LPS 1655 defines rigorous test protocols and performance criteria for personal protection systems, so you can feel confident that your residents are being protected from fire by a robust and tested system.