NCRP Reports 102 - NCRP | Bethesda, MD
2015年6月1日 · NCRP Report No. 102 treats equipment design and use aspects of medical imaging and therapy systems. It supersedes NCRP Report No. 33, Medical X-Ray and Gamma-Ray Protection for Energies Up to 10 MeV—Equipment Design and Use, which was published in 1968 and served the medical radiation community as a basis for the design and use of medical ...
NCRP REPORT No. 102 MEDICAL X-RAY, ELECTRON BEAM AND GAMMA-RAY PROTECTION FOR ENERGIES UP TO 50 MeV (EQUIPMENT DESIGN, PERFORMANCE AND USE) Recommendations of the NATIONAL COUNCIL ON RADIATION PROTECTION AND MEASUREMENTS Issued June 30,1989 First Reprinting February 1, 1995 Third Reprinting February 28, 1997
Report No. 102 – Medical X-Ray, Electron Beam and Gamma-Ray …
Report No. 102 (1989) treats equipment design and use aspects of medical imaging and therapy systems. It supersedes NCRP Report No. 33, Medical X-Ray and Gamma-Ray Protection for Energies Up to 10 MeV, Equipment Design and Use, which was published in 1968 and served the medical radiation community a
AAPM Publications - Report No.102
Report No. 102 (1989) treats equipment design and use aspects of medical imaging and therapy systems.
NCRP Report # 102 • Fluoroscopic Units –Source-to Table-top Distance: •Should not be less than 15 inches (38 cm); •Shall not be less than 12 inches (30 cm). –Primary Protective Barrier: •Must be interlocked with x-ray tube. –Exposure Switch: •Dead-Man type. 69 Equipment Recommendations NCRP Report #102 • Fluoroscopic Units
NCRP Report #102 & 116 Flashcards - Quizlet
Study with Quizlet and memorize flashcards containing terms like maximum radiation intensity at table-top level for each mA of tube operation at 80 kVp, maximum radiation intensity at table-top level Fluoro with NO HLC (high level control) optional mode, maximum radiation intensity at table-top level Fluoro with HLC (high level control) optional...
NCRP 102 Flashcards - Quizlet
Study with Quizlet and memorize flashcards containing terms like max intensity at table top for each mA of tube operation at 80kvp, max intensity at table top. fluoro (no HLC), fluoro with HLC and more.
and NCRP (1993) have yet to be fully implemented in the United States. NRC in 10 CFR 35 Medical Use of Byproduct Material (2002 and 2012) relies upon information provided in several NCRP reports: No. 102, 1989: Medical radiation equipment design, performance and use; No. 105, 1989: Protection for allied health personnel;
NCRP Report #102 - Equipment Design and Regulations Summary - Quizlet
Study with Quizlet and memorize flashcards containing terms like Maximum radiation intensity at table-top - each level of mA of tube operation at 80 kV, Maximum radiation intensity at table-top - Fluoro w/ HLC, Maximum radiation intensity at table-top - Fluoro w/out HLC and more.
NCRP-102 | Medical X-Ray, Electron Beam and Gamma-Ray …
NCRP-102 Medical X-Ray, Electron Beam and Gamma-Ray Protection for Energies Up to 50 MeV (Equipment Design, Performance and Use)