NMD Cables - Electrician Talk
2014年6月6日 · NMD-3 Cloth Jacket NMD-7 Cloth Jacket NMD-7 PVC Jacket NMD-90 PVC Jacket The town I live in was flooded in 1963, so all the house are from this date onward. I see all these types of cable & I am trying to find out what year each cable type came out in order to see what time period the wire would have been installed.
Romex (NMD) in conduit - Electrician Talk
2017年4月29日 · I also know that NMB used in the States has a paper filler that can wick water whereas in Canada we have NMD which does not have paper in it but otherwise appears the same as NMB. I was gonna pull some 10/3 through a pipe to the garage since the conduit was already started but cant readily find if this is acceptable.
Bundling NMD - Canada - Electrician Talk
2020年5月13日 · If wire terminates on equipment you must use the lowest rating, either the wire or the termination temp. You said 4-006 only applies to the first 1.2 meters but what I’m saying is if it is one length of wire, it applies to that whole length. Now if you break it up into more than one length, that is where 4-006(4) can help you. Like in this ...
older nmd wire - Electrician Talk
2015年1月31日 · The wire feeding the 15 Kw furnace is older NMD, and it's blue. Not sure about the colour coding and whether or not it's Nmd 7 or 6. The house was built in the 70's. Any idea what size wire it might be? Thanks in advance.
Transition from Indoor to Outdoor Wiring in Residential
2013年12月11日 · If the pipe does not constitute an “assembly”, it is simply mechanical protection. Once you make it an assembly, they you are required to use the RW or TW types of wire (for wet / underground). Regardless of the size of pipe, you still cannot put NMD wire in a wet location, so the wire need to be W or U rated. Same applies for NMD above ground.
CEC 12-514a), protection of NMD in trusses - Electrician Talk
2021年7月29日 · If you had plywood that made a "barrier" and the cable was run on the vertical on the opposite side of that, I would think that would be suitably protected; however if you look specifically at the rule, the wire is not allowed outside the 1 m distance on the vertical.
NMD90 to PVC conduit - Electrician Talk
2013年1月3日 · wow things get complicated.....imo nmd to L16 female then pvc. Good practice and common sense has to take over sometime. If going underground outside need nmwu.
New wire ampacities - Electrician Talk
2013年12月3日 · With the introduction of the new Ontario code book I have noticed ampacity changes for Tables 1-4. Now NMD 90 has a 90c rating so does that now mean 8/3 NMD90 can be put on a 55amp breaker according to Table 2. There have beensome rather heated discussions amongst some of my collegues. The...
How many nmd wires are allowed in one hole drilled in a...
2013年10月1日 · Also it appears the LVT wire is mixed in with the NMD wire, also a no-no if memory serves. Also that looks like a heating/air duct that the wires are touching, if it's heating duct there has to be 1" of space minimum between the duct and the wire. I can't remember if it is a code requirement but it looks like you've got the stove wire in there too.
Blue NMD 90 for Arc Fault CCT - Electrician Talk
2013年5月5日 · The red colored 12-2 NMD, which is designed for 240V heating circuits cannot be used for counter receptacles or general circuits, as it does not have a white wire. 4-028 Identification of insulated neutral conductors up to and including No. 2 AWG copper or aluminum