PDD curves of 6 MV, 6 MV FFF, 10 MV, 10 MV FFF, and 18
In view of this, the current study analyzes and compares dosimetric characteristics of 6MV flattening filter free and flattened beams of three beam-matched linear accelerators (linacs) from three...
Photon Dose Distributions - Oncology Medical Physics
Percent depth dose (%DD) distributions give the dose, relative to maximum dose, as a function of depth. There are several key features of a %DD chart that should be noted. Skin Sparing. MV photons do not reach maximum dose at the surface/skin but build-up to a maximum dose.
Abstract—In this study the measurements for PDDs were measured using a linear accelerator (Electa synergy) with 6 MV, 10 MV and 12MV photon energies and electron energies of 6MeV, 9MeV and 12MeV at reference field size under constant condition.
Essentials of Depth Dose Calculations for Clinical Oncologists
2020年5月18日 · The table below shows central axis PDD data for a 6 MV photon beam. A patient is prescribed 8 Gy in one fraction to d max on the central axis using a 10 × 10 cm field size. The field size is then changed to 11 × 16 cm. Assuming the MU are corrected to give the same dose at the prescription point, what will be the difference in the dose ...
Evaluation of the dosimetric characteristics of 6 MV flattened …
2017年7月1日 · This work aims to compare and evaluate the dosimetric properties of 6 MV flattening (FF) and flattening filter free (FFF) photon beams which generated from a Varian 2100 medical accelerator. These properties include percentage depth dose, dose rate, beam profile, out-of-field, energy spectra, scatter factor, and surface dose.
Dosimetric characteristics of 6MV flattening filter free and …
2023年7月28日 · In this study we referred to 6MV flattened (FF) photon beam and 6MV flattening filter free (FFF) photon beam, with respective dose rates of 500MU/min and 1200MU/min. For Elekta accelerators, beam matched linacs have identical technical characteristics and multileaf collimator features.
Surface and buildup dose characteristics for 6, 10, and 18 MV …
We performed a comprehensive set of surface and buildup dose measurements with a thin window parallel‐plate (PP) chamber to examine effects of field size (FS), source‐to‐skin distance (SSD), and attenuating media.
直线加速器X射线能量与PDD的关系 - 知乎 - 知乎专栏
2022年7月14日 · pdd的中文名是百分深度剂量,通俗来说,描述了射线能量沉积与模体深度之间的关系,比如在体表处沉积的能量是多少,在某一深度处沉积的能量是多少。
Percept depth dose (PDD) for 6MV photon beam measured by
Percept depth dose (PDD) for 6MV photon beam measured by the PSLD sheet and PTW Semiflex ionization chamber. Dose distributions for photon beam were measured using a Photo-Stimulated...
用测量的6MV医用电子直线加速器X射线能谱验证放疗剂量的初步 …
本研究工作用实验测量的北京医疗器械研究所生产的6MV电子直线加速器X射线谱作为输入数据,计算加速器水箱测量的基本数据PDD和OAR曲线并和实验测量的相应曲线进行比较.这里的X射线能谱是经过MonteCarlo程序EGS4的模拟计算结果验证过的.从比较的结果看,无论能谱 ...