R310.1 - Digital Codes
R310.1.1 Operational constraints and opening control devices. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools or special knowledge.
IRC Code R310 - Emergency Escape and Rescue Required
Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections R310.1.1 to R310.1.3, and such devices shall be releasable or removable from the inside without ...
R310.2.3 - ICC Digital Codes
R310.2.3 Window wells. The horizontal area of the window well shall be not less than 9 square feet (0.9 m 2), with a horizontal projection and width of not less than 36 inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened.
R310.2.2 Window sill height. Where a window is provided as the emergency escape and rescue opening, it shall have a sill height of not more than 44 inches (1118 mm) above the floor; where the sill height is below grade, it shall be provided
R310.1 Emergency Escape and Rescue Opening Required - UpCodes
Window opening control devices and fall prevention devices complying with ASTM F2090 shall be permitted for use on windows serving as a required emergency escape and rescue opening and shall be not more than 70 inches (178 cm) above the finished floor.
Egress Window Requirements | Explained with Illustrations
Where Are Egress Windows Required? (R310.1) The code requires every basement, habitable attic, and every sleeping room to have at least one operable emergency escape and rescue opening. If a room is used as such, it must provide a means of escape.
Emergency Egress for Windows and Doors | Building …
Escape or Egress Requirements for Windows/Doors. IRC SECTION R310.
Section R310.1.1 requires that the required opening dimensions be achieved by the normal operation of the window, door or hatch from the inside without the use of keys, tools or special knowledge. Section R310.1.1 also allows window opening control devices to be used on windows
R310.2.2 Window sill height. Where a window is provided as the emergency escape and rescue opening, it shall have a sill height of not more than 44 inches (1118 mm) above the floor; where the sill height is below grade, it shall be provided with a window well in accordance with Section R310.2.3 R310.2.3 Window wells.
IRC Egress Codes | Emergency Escape & Rescue Openings - Window …
Bars, grilles, covers, screens or similar devices are permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided that the minimum net clear opening size complies with Sections R310.1.1 to R310.2.3, and such devices shall be releasable or removable from the inside ...