Anybody using R-32 in America yet? : r/HVAC - Reddit
R32 is only allowed because we relaxed the combustible standard on refrigerant gasses. The reason R410a is half r32 and half r125 is to bring the flammability down.
Refrigerant ---> R32 vs R-410a : r/hvacadvice - Reddit
2021年10月7日 · R-410A is 50:50 mixture of R-32 and R-125. Systems based on R-32 are newer since R-32 AC will be replacing R-410A in many markets due to lower global warming potential (675:2088). R-32 itself is a better refrigerant than R-410A but is classified as mildly flammable.
R-32 line sets : r/hvacadvice - Reddit
2024年4月28日 · It's a rather large home (~5900sqft) the architect specified 3 units (one 5 tons and two 3 tons) I'm partial to daikin as I installed two in the past on other projects and am happy with them (a DX9 at my brothers and Fit at my dads) My question is regarding copper line sets and how they relate/change with incoming R-32 refrigerant.
Low-GWP refrigerants (R32, R454B) and California : r/hvacadvice
2023年3月15日 · The refrigerant loop is a closed loop, so the actual refrigerant in the system will have zero impact on global warming and during the units expected service life if installed and maintained properly the system should require no additional refrigerant. That said, Systems do fail and leaks can happen so the phase out of R410a is happening, it was pushed back to 2025 for new units because yes ...
Question about vacuum pump (R32) : r/hvacadvice - Reddit
2024年6月5日 · It's using R32 refrigerant. Also, on the exterior unit, there is only one of the two valves to be vacuumed, with a small nipple inside that I guess will close the valve once I'll disconnect the vacuum pump.
Two more sets of gauges for the new refrigerants? : r/HVAC - Reddit
Propane isn’t an A2L, it’s an A3. R32 is already half of what’s in R410A and R454B is almost 70% R32. R32 isn’t a hydrocarbon refrigerant.
R32 refrigerant is coming : r/HVAC - Reddit
2013年11月1日 · R32 has been a constituent part of many refrigerant blends for years (before the VW R32 was conceived!) - it is one of the components of R410A along with all the R407 blends amongst others.
state of things in the USA (r32 banned, r410a to be banned, r32 ...
2022年7月13日 · Get a R410a system now. It won’t be banned immediately it will be a slow phase down. Give the manufacturers a few years to work out the kinks on the new systems with the new refrigerant. Even as techs we aren’t getting a lot of information yet about the new refrigerants and when the systems will be available.
Is this R-410 ban in 2025 really going to happen? Or will it ... - Reddit
R410a is a blend of r32 and r125. 50/50 ratio. R32 is a single molecule refrigerant, it's major downside is high discharge temperature. High discharge temperature will directly corelate to increased compressor failure. This is why most manufacturers are going to r454b. It's 2/3rds r32 and 1/3 r1234yf.
R32 vs R410 vs else? : r/DIYHeatPumps - Reddit
2023年8月11日 · Daikin has R32 units available in the US now. 2025 is the cutoff date for manufactures to switch away from 410a. Some have hinted they with be going with R-454B. I don't know of anywhere that uses CO2 for residential. There are a few using it …