
Pt40 PI-TRV - SAV
The Pt40 PI-TRV balances the heating system 24 hours a day, 365 days a year. Maintaining a low return temperature at all loads minimises energy waste, which results in cost-effective heat delivery. Achieving this requires pressure independent flow …
Pt 40 – Pressure independent, thermostatic radiator valve - SAV
2022年9月30日 · DN 15 radiator inlet valve for 2-pipe systems. Designed for combined actuation and pressure-independent flow control. 10 bar maximum working pressure, locking & limiting features, option for angled or straight-through configuration. Supplied with gas-filled actuator (for sensing air temperature) and lock-shield valve for radiator outlet. Capillary connection offered where valve location must ...
Pt40 Pressure Independent TRV Configurator - YouTube
2023年10月20日 · All our Pt40 Pressure Independent TRV sets are bespoke to the specific building requirements. To help you choose the correct radiator valve set you can use t...
Technical Datasheet Pt40 Presetting The Kv setting of Pt40 valves can be adjusted easily and accurately without the use of tools (default setting = N). Presetting can be selected in steps from 1 to 7: • Remove protective cap / thermostatic sensor. • Find reference mark (R). • Turn setting ring until the required presetting aligns with the
Pt40 Pressure Independent Thermostatic Radiator Valve (PITRV) Rt40 Pressure Independent Return Temperature Limiting (Towel Rail) Valve (PIRTLV) ... SAV can accept no responsibility for possible errors in datasheets, catalogues, brochures and other printed material. SAV reserves the right to alter its products without notice.
Pressure Independent Space Heating Control | SAV Systems | NBS …
This results in additional energy savings of 5-8% when compared with liquid-filled thermostatic sensor heads. Rt40 has a 40°C maximum return temperature limiting, protect the network’s performance without compromising the comfort of occupants. Settings schedules - equipped with a clear Pt40, Rt40, Ft40, flow setting schedules for each ...
SAV’s new PT40 valves help maintain low heating system …
2015年11月30日 · SAV Systems has introduced PT40 radiator control valves, which help to reduce energy waste in heat networks through well-balanced radiator systems. The TRV sets are pre-settable to a flow rate limit at each radiator, in line with the CIBSE Heat Networks: Code of Practice, eliminating the need for traditional balancing.
Flow-limiting valves help maintain low system temperatures
2016年1月5日 · The PT40 range of radiator control valves from SAV Systems helps to reduce energy waste in heat networks by ensuring that radiator systems are well balanced. These TRV sets are presettable to a flow-rate limit at each radiator, in line with the CIBSE ‘Heat networks code of practice’, eliminating the need for traditional balancing.
Configurator Pt40 - SAV
Scandia House, Boundary Road, Woking, Surrey GU21 5BX +44 1483 771910; [email protected]
SAV Systems | HVR Awards 2024
– 14,000 Pt40 hydronic balancing TRV sets (since 2016) But these are only the numbers; our end-to-end approach is what makes us stand out; from design stage, through delivery to operation. ... This initiative builds on a longer-term relationship between the two companies that has seen SAV voted Manufacturer of the Year by JS Wright for three ...
- 某些结果已被删除