CTech™ SoloVPE® PLUS System - Repligen
The SoloVPE PLUS System reports concentration results in less than 30 seconds. Capable of making spectral and fixed-point measurements at wavelengths between 190 nm and 1100 nm at pathlengths between 2 microns and 15 millimeters, the SoloVPE PLUS solution is adaptable to a wide range of sample types and concentrations. The variable pathlength ...
The SoloVPE System is the technological innovation behind the Slope Spectroscopy® technique. Unlike traditional UV-Vis methods that rely on a single Absolute Absorbance value, Slope Spectroscopy methods use Section Data (Absorbance vs. Pathlength Data) to determine a slope value for quantitation of sample concentration using the Slope ...
CTech™ SoloVPE® System (V3 Software) User Guide . 2 DOC0126 eRev. 11/17/2023 11/17/2023 CTech™ SoloVPE® System (V3 Software) User Guide The information contained in this document is subject to change without notice. With respect to documentation accompanying Product Repligen makes no warranty, express or implied. Any and all warranties
relationship allows the SoloVPE System to report concentration results in less than 60 seconds. apable of making spectral and fixed-point measurements at wavelengths between 190 nm and 1100 nm and at pathlengths between 5 microns and 15 millimeters, the SoloVPE System is adaptable to a wide range of sample types and concentrations.
relationship allows the SoloVPE System to report concentration results in less than 60 seconds. apable of making spectral and fixed-point measurements at wavelengths between 190 nm and 1100 nm and at pathlengths between 5 microns and 15 millimeters, the SoloVPE System is adaptable to a wide range of sample types and concentrations.
SoloVPE System use. It is critical to remember to pull the Fibrette Optical omponent down slightly (2–10 mm) after it touches the Delivery Fiber. It is better to err on the side of pulling down too much rather than too little, especially when measuring highly concentrated compounds. When wearing gloves, users
Protein Concentration Measurement Using A280 - Repligen
CTech™ SoloVPE ® System. CTech™ SoloVPE ® System provides at-line concentration values in less than 2 minutes, with no need to send samples off to QC labs for process-disrupting concentration checks.. VPT allows the direct measurement of proteins, including monoclonal antibodies (mAbs), which absorb light at 280 nm due to aromatic amino acids (primarily L …
the SoloVPE instrument’s back panel. The silver connector is keyed. To properly position the connector for insertion, align the red dots on the connector and the port and push firmly to make the connection to the back panel. Step 7: Attaching SoloVPE Strain Relief The Delivery Fiber Strain Relief is shipped with the SoloVPE instrument but
The CTech™ SoloVPE® System is the technological innovation behind the Slope Spectroscopy® method. Unlike traditional ultraviolet-visible (UV-Vis) methods that rely on a single absolute absorbance value, the SoloVPE System uses section data (absorbance vs. pathlength) to determine a slope value for quantitation of sample concentration ...
The SoloVPE® System (comprising the Microsoft Windows operating system, Agilent Technologies Cary WinUV spectroscopy Environment, and C Technologies, Inc. SoloVPE software) provides compliance with the FDA’s ruling on electronic records and electronic signatures. As the capabilities and functions available in the software alone cannot ...