GC sulfur chemiluminescence detection, sulfur analyzer | Agilent
2020年4月28日 · The Agilent 8355 SCD is a major advance in sulfur chemiluminescence detection, with improved technology that is more reliable and easier to use. It is highly sensitive and specific with a simplified burner design. A dual-plasma burner achieves high temperature combustion of sulfur-containing compounds to form sulfur monoxide (SO).
DB-Sulfur SCD 气相色谱柱 | 安捷伦 - Agilent
Agilent J&W DB-Sulfur SCD 色谱柱经过优化,可与硫化学发光检测 (SCD) 一起使用,以实现低流失性能,减少 SCD 陶瓷管污染。 DB-Sulfur SCD 色谱柱能够让所有采用 PDMS 固定相的 GC/SCD 方法(例如 ASTM D 5623 和 5504)都获得优异的峰形,同时提高检测器稳定性,减少 …
Sulfur chemiluminescence detection (SCD) is known as an excellent device for sulfur compound analysis because its response is inherently linear, equimolar, and far less susceptible to hydrocarbon interference. For example, ASTM Method D5623-94 uses SCD for the detection of sulfur compounds in gasoline.
Chapter 8 The sulfur chemiluminescence detector - ScienceDirect
1995年1月1日 · This chapter discusses a sulfur chemiluminescence detector (SCD). Many analytic techniques have been developed for the measurement of the sulfur content of petroleum and petroleum products.
Preparation of SF6 for sulfur isotope analysis by laser heating sulfide ...
1993年9月1日 · Laser fluorination of powdered samples, previously analyzed by conventional bulk SO 2 or BrF 5 methods, verifies that comparable precision and accuracy can be achieved with the new method. The δ34SCDT and δ33SCDT values of powdered samples are independent of F 2 gas pressure over a range of from 15 to 120 torr.
SCD Technology | Research & Development - SHIMADZU …
In a sulfur chemiluminescence detector (SCD), samples (sulfur compounds) eluted from a GC column are injected into a burner to cause oxidation and reduction reactions. Then the samples (SO radicals) are sent to a reaction cell, where they collide with ozone, which generates light emission that is detected by a photomultiplier.
Trace Sulfur Analysis by SCD and Other Detectors - PerkinElmer
PerkinElmer’s portfolio of trace sulfur analyzers utilize gas chromatography techniques with a sulfur chemiluminescence detector (SCD) to detect sulfur at part per billion levels. A programmable pneumatic control is utilized on our trace sulfur analyzers to use precise and automated gas flow, ensuring your quality and productivity objectives ...
Sulfur chemiluminescence detection using SCD-2030 enables selective detection of sulfur compounds in high matrix load petrochemical samples down to low concentration levels. Its excellent selectivity and reproducibility ensure reliable results, while equimolarity for different sulfur target species facilitates the analysis of unknown sulfur ...
Sulfur Chemiluminescence Detection (SCD) with Nexis SCD -2030 enables the reliable analysis of total sulfur content in petrochemical samples Additionally, and in contrast to classical total sulfur approaches, it offers the possibility to detect and quantify individual sulfur compounds, revealing the sulfur pattern of a certain sample Y. Nagao
Applications of sulfur isotope geochemistry: Using sulfur isotopes to indicate the primary mechanism of PGE mineralisation in magmatic sulfide deposits . In mineralisations related to mafic (basaltic) magmas, sulfur isotopes can be used to distinguish between sulfur-rich magmatic systems, in which copper and nickel are
- 某些结果已被删除