Trane XB80 2 issues? - DoItYourself.com Community Forums
2011年11月17日 · I have a trane furnace XB80. Model # TDE080A945M1. I assume it is 80,000 btu. My house is approx 2100 sq ft 2 story. It is 32 deg outside now and 26 with the windchill. I have a basic honeywell digital thermostat. It CANNOT be programmed to set hi and low temps throughout the day. It only allows me to have 1 set temp.
Trane XB80 Ignition Trouble - DoItYourself.com
2012年11月18日 · Gas and Oil Home Heating Furnaces - Trane XB80 Ignition Trouble - I have a Trane XB80 furnace. For the last few years, it would intermittently fail to ignite and go into lockout mode. Cleaning the flame sensor has always resolved the issue. The “fix” would typically last the heating season and then I would need to
How/where to clean (replace?) Trane XB80 filter
2010年8月29日 · Trane XB80 filter - The User's Information Manual for my Gas Furnaces -- Non-Condensing Fan Assisted Combustion System Upflow/Horizontal and Downflow / Horizontal is pretty straight forward, and even comes with pictures of how to maintain my filter.
Trane XB80 error code 4 and no ignition, Limit switch OK!
2015年6月7日 · I have Trane xb80 furnance blowing cold air, I opened the panel and I found the red light blinking 4 times. Everything else is working except no ignition. I did some research and found that it's Open Limit Switch Issue. I located the temperature limit switch, tested it continuity test by the multimeter and it's working (sound peeps with the test).
Trane XB80 Heating issues - DoItYourself.com Community Forums
2013年11月22日 · Heat Pumps and Electric Home Heating - Trane XB80 Heating issues - Replaced ignitor Replaced flame sensor, needlessly Issue: furnace will ignite and run maybe 15-20 minutes then shuts off, immediately tries to restart. The only thing flashing is fast flash calling for heat. Igniter lights then extinguishes and furnace
Trane XB80 furnace, no gas ignition - DoItYourself.com
3. trane Xb80. MFG date- 11/2002, Model no. TUE080A948L1, Serial no. 2474EUF1G 4. newer Honeywell wifi thermostat The issue-When my furnace gets the call for heat, everything seems to start working as it is supposed to. At least until there should be a flame.
Trane XB80 runs intermittently - HVAC TECH GROUP
2020年1月2日 · I've got a Trane XB80 that was installed in 2002 when the home was built. In the past week or so it's begun to operate intermittently meaning it doesn't always provide heat when called for. Last night I can see in the data from the thermostat that there was a 2.5 hour period where the thermostat called for heat and the room temperature didn't ...
Trane XB80 furnace not igniting - DoItYourself.com
2018年10月17日 · Gas and Oil Home Heating Furnaces - Trane XB80 furnace not igniting - Like title says it's not igniting. LED flashes normal call for heat constantly. The inducer motor spins the entire time when trying. Ignitor is working and getting hot like it should. It will heat up for 20-30 secs then cool down and try again. Once
Trane furnace: flame turning on and off - DoItYourself.com
2021年12月28日 · I have a Trane XB80 furnace and a 5055-3797 White Rodgers control board where the flame keeps cycling on and off. I checked the high limit on the control board and it is reaching the limit and the limit switch is turning the flame off while the blower and the exhaust fan continue to run. It waits a while and then turns back on when it cools off.
Honeywell HE260 and Trane XB80 - DoItYourself.com
2012年2月10日 · Humidifiers and Dehumidifiers - Honeywell HE260 and Trane XB80 - Hi, earlier this week I installed a Honeywell HE260 on my Trane XB80 furnace. I've realized that the pressure switch is a real piece of junk - or the instructions don't specify well enough exactly where to position it. A lot of other people have had the