Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance
The table on the following pages lists the UL fire rated assemblies that include Vulcraft composite and non-composite decks profiles. This summary table is provided to assist in identification of assemblies to meet specific project requirements. Refer to the particular UL assembly for full details of construction including, specific
UL FIRE RATED ASSEMBLIES UL Fire Resistance Ratings Restrained Assembly Ratings (hr.) Type of Protection Concrete Thickness & Type UL Design No. Deck Type Unrestrained Beam Rating 2D 3.5D (hr.) 110 Unprotected Deck 2" LW & 23/4" NW D904 ü 3/4 D961 ü 3/4 D917 ü D928 ü 3/4 11/2 Unprotected Deck 2" LW & 2" NW D947 ü D964 ü D984 ü 2 ...
Floor-Ceiling Assemblies, UL Fire Rated Floor & Ceiling Designs - USG
Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly.
fire-resistance ratings - ansi/ul 263 (bxuv) 109 mination, see Design Information Section, Sprayed Material. The Spray-Applied Fire Resistive Materials shall be applied to the floor
Product iQ | UL Solutions - UL Prospector
Product iQ is UL Solutions' online location for certification information. It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience.
UL ratings for the Dovetail composite deck system range from 1 hour to 3 hours per UL #D904, and are achieved without protection of the deck by an additional fire-rated ceiling assembly. ADVANTAGES: • Long Spans • Thin Slabs (less concrete) • Standard Wall Fireproofing techniques CONSIDERATIONS: • Shoring/Re-shoring requirements.
ASC Steel Deck has been evaluated for fire resistance per UL 263 Fire Tests of Building Construction and Materials. See UL directory for fire rated assemblies.
CAFCO 300 Series & CAFCO 400 Series UL Designs - Isolatek International
UL Designs & Thicknesses for CAFCO 300 and CAFCO 400 Series passive fireproofing materials for the commercial and construction industry. (973) 347-1200 Select language
FIRE RATED ASSEMBLIES
Our ComSlab® Floor system has been fire rated by UL and ULC. Learn more!