Shallow Well -- Advice on plumbing needed *with pictures!*
2011年8月5日 · The pipe works great but my 3/4 hp shallow well pump is struggling to maintain a prime. After consulting with some locals it appears I should have used 1" or 3/4" pipe from the well and into the house.
What size of pipe for a water line from well to house?
2014年11月30日 · 1" pipe, 23 psi pressure drop for PVC, 33 psi for galvanized 1.5" pipe, 3 psi pressure drop for PVC, 3.7 psi for galvanized 2" pipe, 0.9 psi pressure drop for PVC, 1.05 psi for galvanized While PVC will give better performance than galvanized with respect to pressure drop, both are acceptable materials.
Shallow Well - Check Valve - Homesteading Forum
2014年6月23日 · We drove a shallow well down about 15' deep, and the water (static level) is only down about a foot (below ground level). I can see the water in the pipe. I didn't put a foot valve, or check valve, at the bottom of the galvanized pipe - I instead put it …
Easier way to pull a well pump - Homesteading Forum
2004年11月21日 · Fordy, to hold the pipe remaining in the well as you remove the joints I use a pair of modified vise grips. I have two short 6 inch long pieces of angle iron welded to the jaws. I carefully set the pliers to where they just grip the pipe. I remove the joint above the coupling therefore if the pipe does slide downward it will catch on the coupling.
Firing a .22 down the well - Homesteading Forum
2017年11月5日 · Lots of different well systems. Is the single galv. pipe go inside the well, like a 1/2 or 3/4 pipe or is the well itself the only pipe, likely 1 1/8 to 2"? The well setup is different for a shallow well, where the water level is less than 25 feet from the surface, or deep well, where there is usually two pipes.
How to keep water pipe from slipping down well?
2009年12月8日 · I need to replace my deep well jet pump, the jet is down in the well(60ft), the defunct pump is at the top of the well. I basically need to pull up the pipe a couple of feet and hack off my pump and install new unit/plumbing at the top of …
Pulling you well - Homesteading Forum
2008年5月9日 · You can let the pipe back down into the well a bit and let the pipe rest on the couping and the setup cannot fall into the well. With a pipe wrench on the coupling unscrew the pipe above the coupling and remove the upper pipe. Leave the coupling attached to the section of pipe that is still in the well.
Water well rejuvenating??????????? - Homesteading Forum
2011年6月20日 · The well had a cylinder and pipe in it so isn't a driven well. rambler has it right, you will need to pump the well to test it. Generally around here a well driller will install a temporary submersible pump and operate it with a generator. They pump it for at least a couple of hour and then test the flow buy timing and catching a certain amount.
build something to pull a well pump? | Homesteading Forum
2014年6月12日 · Before I got my new pump plumbed in I managed to break the pipe at the top of the well head but I had the wire for the pump tied to it so it didn't fall all the way down. I was used to dealing with 300+ feet wells with 21 foot sections of galvanized pipe so I called the pump guy to tell him I needed him to come out an pull the pump.
Adding a hand pump to a well - Homesteading Forum
2023年11月7日 · Before the new pump went in, I pulled the downpipe, at the direction of the contractor, it seems to me it was no more than about 15 feet to water and about 25 feet to the "foot". With a 2" pvc pipe in a 3" casing, I think fitting another pipe in the casing is doubtfull. Currently in the casing is a pvc pipe down the "foot".